16 resultados para Eletroforese capilar

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thin lens method, used for the interpretation of interferometric data - obtained from smectic liquid cristals, has been modified. The analysis employed has - been derived from the one presented by Granjean. The theoretical results are in a good agreement with the experimentals values from other authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El establecimiento de políticas de vigilancia y protección del suelo exige la validación de métodos de análisis eficaces para determinar la calidad del suelo y hacer posible su evaluación en relación con su estado de contaminación. Para poder caracterizar el suelo desde el punto de vista de su vitalidad, se han investigado los Métodos de Formación de Imágenes (Bildschaffende Methode) y en particular los métodos de Dinamolisis Capilar (Steigbild Methode) desarrollados por L. Kolisko. Partiendo de la configuración horizontal conocida como Chroma-Test, propuesta por E. Pfeiffer, se han identificado las modificaciones del método original que hacen posible su validación. A continuación se han verificado realizando ensayos ciegos colaborativos y comparando los resultados con los obtenidos por otros métodos experimentales utilizados para evaluar la fertilidad del suelo. Como caso práctico se presenta una investigación en el antiguo distrito minero de plomo de Linares, situado en Jaén, España. Esta investigación sienta las bases para un avance significativo en la evaluación de los suelos y su posible calificación como contaminados. El método Horizontal de Dinamolisis Capilar propuesto permite identificar de forma simple y directa los efectos inhibidores de las funciones del suelo debidas tanto a la contaminación puntual o local como a la contaminación difusa. AB S TRACT Establishing policies for Soil protection and monitoring, requires the validation of effective analytical methods for determining soil quality and assess the state of contamination. The possibilities of Image Forming Methods (Bildschaffende Methode), and in particular the methods of Capillary Dynamolysis (Steigbild Methode) of L. Kolisko have been investigated in order to characterize soil quality from the point of view of its vitality. Based on the horizontal configuration known as Chroma-Test, proposed by E. Pfeiffer, the amendments to the original method that enable validation have been identified, and then verified through collaborative blind tests and through comparison with results provided by other experimental methods often used in agriculture to assess soil quality. As a case study the investigation at the former lead mining district of Linares, located in Jaen, Spain, is presented. This research lays the groundwork for significant progress in the assessment of soils and their possible declaration as contaminated. The proposed Horizontal Capyllary Dynamolysis Method allows to identify in a simple and direct way the inhibiting effects on soil functions due to both local contamination and/or diffuse contamination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El entrenamiento con cargas es una actividad anaeróbica glucolítica intensa y se ha comprobado que el error en las estimaciones del gasto energético en esta actividad varía entre un 13 y un 30%. El principal objetivo de este trabajo es describir la contribución anaeróbica de energía en un circuito con cargas. Doce hombres (20-26 años) y diecisiete mujeres (18-29 años) estudiantes de Ciencias de la Actividad Física y del Deporte realizaron un entrenamiento en circuito de cargas a 6 intensidades diferentes (entre el 30% y 80% de su 15RM). Durante la totalidad de los circuitos se registró el gasto energético aeróbico por calorimetría indirecta, la frecuencia cardiaca con pulsómetro Polar® y la concentración de lactato en sangre capilar para medir la contribución anaeróbica. El incremento que produjo la energía anaeróbica se situó entre el 5,1% y un máximo del 13,5%, lo que hace evidente que medir o no la contribución anaeróbica en el entrenamiento en circuito puede provocar un error medio del 9,65%. Existen diferencias significativas (Pmenor que 0,05) entre el gasto energético aeróbico y total (aeróbico+anaeróbico) en todas las intensidades, en un circuito de entrenamiento con cargas a intensidades progresivas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las diferencias individuales ante cualquier estímulo son parte de la condición humana, y reflejan nuestra diversidad genética, así como la influencia del entorno. Conocer el papel que juegan las variaciones genéticas o polimorfismos, es vital para entender de forma integral la respuesta del organismo al ejercicio. Por tanto, el presente trabajo tiene como objetivo fundamental definir el posible rol de tres variantes genéticas en el metabolismo energético durante la realización de ejercicio físico. Más concretamente, los objetivos principales son, por un lado, observar si existen diferencias en la respuesta láctica en sangre capilar y venosa en función del polimorfismo A1470T del gen del Transportador de Monocarboxilatos 1 (MCT1) (rs1049434). Por otro lado, el segundo objetivo es estudiar si presencia del polimorfismo del gen MCT1 determina parcialmente la máxima concentración de lactato en sangre venosa alcanzada durante diferentes protocolos de circuitos de fuerza. Por último, los objetivos tercero y cuarto se centran en analizar si existen diferencias en las ratios de acilcarnitinas en sangre, que reflejan la actividad de la Carnitina Palmitoiltransferasa II (CPTII), en función de los polimorfismo Val368Ile (rs1799821) y Met647Val (rs1799822) del gen de la CPTII (CPT2) durante la realización de una sesión de Circuito Mixto de musculación-aeróbico. Para la consecución de estos objetivos se realizaron dos estudios (Piloto y General). En el primero de ellos (Estudio Piloto) 10 hombres estudiantes de la Licenciatura en Ciencias de la Actividad Física y del Deporte (CCAFD) realizaron 6 sesiones de fuerza en circuito. En días no continuados y a una intensidad diferente (30%, 40%, 50%, 60%, 70% u 80% de la 15 repetición máxima, 15RM), los sujetos ejecutaron tres vueltas a un mismo circuito de 8 ejercicios. A lo largo de la sesión se tomaron muestras de sangre capilar para el análisis de la concentración de lactato. En el Estudio General, 15 hombres y 14 mujeres estudiantes de la Licenciatura en CCAFD realizaron 3 protocolos de fuerza en circuito, al 70% de la 15 RM y al 70% de la reserva de la frecuencia cardiaca. Cada día ejecutaron un protocolo diferente: Circuito de Máquinas, Circuito de Peso Libre o Circuito Mixto de musculación- aeróbico, completando en cada uno tres vueltas. Durante cada una de las sesiones se extrajeron muestras de sangre venosa para el análisis de la concentración de lactato y del perfil de acilcarnitinas. Los resultados del presente trabajo evidencian que los sujetos portadores del polimorfismo A1470T del MCT1 (genotipos AT y TT) tienen un comportamiento de lactato diferente que los sujetos no portadores (genotipo AA) cuando se someten a diferentes circuitos de fuerza. En el Estudio Piloto los portadores tuvieron mayor pendiente de acumulación de lactato capilar a la intensidad del 80% de la 15RM, mientras que en el Estudio General los sujetos homocigotos para la variante genética (TT) registraron menores concentraciones de lactato venoso que los homocigotos normales (AA) durante el Circuito de Máquinas. No podemos concluir si esta diferencia de resultados se deriva del tipo de sangre analizada (capilar VS. venosa), de la existencia de un efecto umbral para el transportador o de una bidireccionalidad del MCT1, aunque la hipótesis de bidireccionalidad parece la más integradora. En el grupo de mujeres, no se observó un patrón claro de diferencias entre grupos genéticos por lo que no podemos concluir si el polimorfismo tiene efecto o no en este sexo. En el estudio 2 del Estudio General, la inclusión la variante del MCT1 como variable predictora cuando las variables dependientes fueron la máxima concentración de lactato venosa en los tres protocolos en conjunto, o la máxima concentración venosa durante el Circuito de Máquinas, confirma su influencia en los entrenamientos con elevada producción de lactato. No obstante, en los entrenamientos con concentraciones de lactato más bajas, parece que existen factores más determinantes para la máxima concentración que el polimorfismo del MCT1. Por último, los resultados del tercer estudio del Estudio General, aunque preliminares, sugieren que la presencia de las variantes polimórficas del CPT2 podría influir sobre el transporte de los ácidos grasos durante la realización de actividad física, particularmente en hombres. Aún así, son necesarios más estudios para confirmar, especialmente en mujeres, la influencia de ambos polimorfismos en la actividad de la CPTII.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El trabajo realizado ha pretendido desarrollar y caracterizar una solución de revestimiento continuo interior con características de barrera de vapor e higroscopicidad. El objetivo ha sido desarrollar una solución de revestimiento continuo interior, capaz de reducir el riesgo de condensación intersticial en los cerramientos, manteniendo la capacidad de regulación de la humedad del ambiente interior. ESTUDIO DE ANTECEDENTES 1 La condensación intersticial La condensación intersticial se produce cuando la presión de vapor sobrepasa la presión de vapor de saturación en una de las capas internas del cerramiento. El vapor de agua se transfiere de los locales de mayor presión de vapor a los de menor presión. Para la situación de condensación intersticial, en la estación de calentamiento, las presiones de vapor son más elevadas en el interior del edificio que en el exterior. Entonces existe una transferencia de vapor del interior hacia el exterior y es en ese trayecto cuando pueden producirse las condensaciones intersticiales si éste alcanza la temperatura de rocío. Las consecuencias de la condensación intersticial pueden ser varias, desde la degradación de los materiales, como la corrosión de elementos metálicos; la pudrición de productos orgánicos naturales, como la madera, variaciones dimensionales de las fábricas de ladrillo con posibilidad de deformación del cerramiento y de fisuración de los revestimientos continuos. Pueden también producirse fenómenos de corrosión física provocados por la congelación del agua en los elementos porosos del cerramiento. Los revestimientos continuos pueden también estar sujetos a vegetaciones parasitarias por el exterior del cerramiento o de hongos por el interior, por transferencia del agua condensada a las superficies del cerramiento. Los hongos pueden provocar enfermedades principalmente respiratorias o alergias, al alterar la calidad del aire. La condensación intersticial se produce principalmente en situaciones de bajas temperaturas y elevados grados de humedad especifica exterior. Pero las condiciones de temperatura y principalmente de humedad especifica interior tienen también gran influencia en esta situación patológica. Las condiciones de humedad relativa interior dependen de muchos factores como el tipo y uso del edificio, y en caso de vivienda, del número de ocupantes, de las actividades que se desarrollan, pero esencialmente de la temperatura interior y del grado de ventilación. Las soluciones constructivas también tienen influencia en el riesgo de condensaciones. Las soluciones de cerramientos con aislamientos por el interior y con capas impermeables al vapor por el exterior son las más problemáticas. En esta solución constructiva extrema, tenemos prácticamente todo el cerramiento cerca de las temperaturas exteriores, con gran concentración de vapor de agua. El tipo de aislamiento también es importante, los aislamientos con gran desequilibrio higrotérmico, como las lanas minerales, de fibra de madera, o de fibras textiles, caracterizados por el elevado aislamiento y la elevada permeabilidad al vapor, son los que presentan mayor riesgo. Éstos permiten el paso del vapor y producen un salto acentuado de la temperatura. Su colocación por el interior de los cerramientos incrementa aún más el riesgo de condensaciones. Estos materiales de aislamiento también se caracterizan por tener una menor energía primaria asociada a su fabricación. Por lo tanto merecen una atención especial en la búsqueda de soluciones sostenibles. Así mismo, también puede existir riesgo de condensaciones con aquellos aislamientos de menor permeabilidad al vapor, como los poliméricos o las espumas de vidrio, pero deficientemente aplicados, permitiendo el paso del vapor de agua por las juntas o en los encuentros con forjados, pilares o huecos. La condensación de agua en los aislamientos caracterizados por una elevada permeabilidad al vapor es la situación más problemática porque, además de poder conducir a la pudrición de aislamientos de origen orgánico (como los de fibra de madera), conduce a una disminución del aislamiento del cerramiento y al consecuente incremento del consumo de energía en la obtención del confort térmico. Existen un conjunto de reglas y de soluciones constructivas que pueden reducir el riesgo de condensaciones intersticiales como la colocación de materiales sucesivamente más permeables al vapor, o más aislantes, del interior al exterior. XXXIII Revestimientos exteriores discontinuos y ventilados y aislamientos aplicados por el exterior es la solución extrema de este principio. La aplicación de aislamientos impermeables al vapor es otra solución, siendo necesario que se garantice que las juntas de las placas del aislamiento sean estancas, así como los encuentros con los forjados, pilares y huecos. Otra solución es la aplicación de cerramientos dobles con cámara de aire ventilada, teniendo el cuidado de ventilar solamente la parte fría del cerramiento. Es necesario en estas situaciones, que se garantice que el aislamiento se encuentra aplicado en la cara exterior del ladrillo interior del cerramiento. También es importante controlar el grado de ventilación de la cámara para que no se produzca la pérdida de la resistencia térmica de la hoja de ladrillo exterior. La aplicación de barreras de vapor en la parte caliente del cerramiento es una solución que garantiza la reducción del flujo del vapor del interior hacia el exterior y consecuentemente contribuye a la reducción de la presión de vapor en su lado exterior y en la parte fría del cerramiento. 2 La normativa La normativa española, el Código Técnico de la Edificación de 2006, en su capítulo Ahorro de Energía, establece que no está permitida en ninguna situación, la condensación en el aislamiento. Todavía existiendo condensaciones en otras capas del cerramiento, en la estación de calentamiento, éstas no pueden ser mayores que la evaporación en la estación de enfriamiento. La misma normativa determina que si existe una barrera de vapor en la parte caliente del cerramiento no será necesario comprobar las condiciones anteriores. La normativa portuguesa, el Regulamento das Características do Comportamento Térmico dos Edifícios, de 2006, no tiene ninguna exigencia relativa a las condensaciones intersticiales. Sus autores defienden que en Portugal no es un fenómeno que pueda tener consecuencias graves en los elementos constructivos o en el consumo de energía. En la norma EN 13788 de 2001 están definidos los métodos más comunes de verificación de las condensaciones y de la evaporación y están basados en el Diagrama de Glaser. En base a esta norma es posible verificar el riesgo de condensaciones superficiales y la posibilidad de desarrollo de hongos en la superficie interior del cerramiento. Pero también permite evaluar el riesgo de condensaciones debido a la difusión de vapor de agua. En este método se considera que el agua incorporada en la construcción ha secado, y es aplicable en situaciones en que sean insignificantes los fenómenos de alteración de conductividad térmica con la humedad, la liberación y absorción de calor, alteración de las propiedades de los materiales con la humedad, succión capilar y transferencia de humedad líquida en los materiales, circulación de aire a través de grietas, y la capacidad higroscópica en los materiales. Me resulta extraño que la misma norma establezca que el método no debe ser utilizado para la comprobación de la existencia de condensaciones, sino solamente como método comparativo de diferentes soluciones constructivas o condiciones ambientales. Más recientemente, con la norma EN 15026 de 2007, se ha introducido una alteración en el método de verificación. Mientras que en base a la norma 13788 la verificación se realiza en régimen estacionario, y solamente considerando algunas propiedades de los materiales como la resistencia térmica (R) y el coeficiente de resistencia a la difusión de vapor de agua (μ), la norma EN 15026, determina que se realice en régimen variable y que otros fenómenos físicos sean considerados. Con respecto a la temperatura, el almacenamiento de calor en materiales secos o húmedos, la transferencia de calor con la transmitancia térmica dependiente de la cantidad de agua presente en los materiales, transferencia de calor latente por difusión de vapor de agua con cambio de fase. Con respecto a la humedad, el almacenamiento de humedad por adsorción y desorción de vapor de agua y fuerzas capilares. Transporte de humedad por difusión de vapor de agua, transporte de agua líquida por difusión de superficie y conducción capilar. 3 Barreras de vapor Las barreras de vapor se caracterizan por una reducida permeancia al vapor, que de acuerdo con la normativa española NBE 79 es inferior a 0,1g /MNs o resistencia superior a 10 MNs/g. (o permeancia inferior a 1,152 g/mmHg, o resistencia al vapor mayor que 0,86 mmHg∙m2∙día /g). Esta permeancia al vapor corresponde a una capa de aire de difusión equivalente (Sd) de 215 cm o 2,15 metros. XXXV Todos los materiales pueden alcanzar estos valores de resistencia al vapor siempre que se utilicen con grandes espesores, pero los que más interesan son los que puedan tener esa característica con pequeños espesores. Existen otras clasificaciones, como la del CSTC de la Bélgica que divide los materiales de acuerdo a su permeancia al vapor. Están definidas 4 categorías de barreras de vapor E1, E2, E3, E4. La categoría E1 para los materiales con - Sd entre 2 y 5 metros, E2 – con Sd entre 5 y 25 metros y 3 - con Sd entre 25 y 200 metros y finalmente E4 para valores de Sd superiores a 200 metros. Estos materiales pueden ser de diferentes tipos, y con diferentes aplicaciones. Las pinturas al esmalte o emulsiones bituminosas, los films de polietileno o de aluminio, y las membranas de betún o vinílicas son algunos ejemplos de productos con estas características y que se utilizan con ese fin. Su aplicación puede realizarse en la superficie interior del cerramiento como las pinturas al esmalte o en la cámara de aire como los otros tipos mencionados anteriormente. En todo caso deben ser colocados en la parte caliente del cerramiento, por el interior del aislamiento. Las pinturas al esmalte, los barnices, o las membranas vinílicas, cuando son aplicados sobre el revestimiento interior, presentan el problema de quitar la capacidad higroscópica del revestimiento, sea de yeso, mortero de cemento o incluso de madera. Las emulsiones de betún o las membranas de betún son generalmente aplicadas en la cara exterior de la hoja interior del cerramiento, cuando existe cámara de aire, por lo que necesitan ser aplicadas por el exterior del edificio y obligan a que la ejecución de la hoja de ladrillo de fuera sea hecha también por el exterior, con las condiciones de seguridad y de costo asociadas. Los films de aluminio o de polietileno presentan problemas de aplicación como la garantía de estanquidad, por no ser continuos, y por que el sistema de fijación poder no garantizarla. Las soluciones que parecen garantizar una mejor estanquidad y menor costo son las aplicaciones de barreras de vapor continuas y aplicadas por el interior del cerramiento, como la pintura al esmalte. Sin embargo, como ya se ha comentado con anterioridad, pueden reducir la capacidad higroscópica de los cerramientos y la inercia higroscópica de las construcciones. 4 La importancia de la capacidad higroscópica El agua actúa como un pequeño imán y es atraída por varios materiales en estado líquido o gaseoso. Muchos materiales son capaces de contener moléculas de vapor de aire, llamándose este fenómeno adsorción y ocurre en los materiales llamados hidrófilos. La capacidad de los materiales de variar su contenido de humedad con la humedad relativa del aire se llama capacidad higroscópica. La capacidad higroscópica de los materiales de revestimiento es importante por permitir la adsorción y desadsorción de agua en estado de vapor y así permitir la regulación de la humedad del ambiente interior, adsorbiendo cuando la humedad relativa del aire es elevada y desorbiendo cuando la humedad relativa es baja. De acuerdo con los datos del Fraunhofer Institut y para valores de humedad por unidad de volumen (Kg/m3), el revestimiento de yeso no es el producto que presenta una mejor capacidad higroscópica, comparado por ejemplo con los revocos de cemento. Para valores de humedad relativa del 50%, el revestimiento de yeso presenta valores de contenido de humedad de 3,6 g/m3, el revoco de cemento 9,66 g/m3, y el revestimiento acrílico de acabado de 2,7 g/m3. Para una humedad relativa del 95% y por tanto aún en el rango higroscópico, los valores para los mismos morteros son de 19 g/m3, 113,19 g/m3 y 34,55 g/m3, respectivamente. Para una humedad relativa del 100% y por tanto en el rango por encima de la saturación capilar, en la saturación máxima, los valores son de 400 g/m3, 280 g/m3 y 100 g/m3 respectivamente. Solo para valores de humedad relativa del 100% es posible verificar un contenido de humedad del revestimiento de yeso superior al del revoco de cemento. La inercia higroscópica permite que las variaciones de la humedad relativa del aire en una habitación, tenga una atenuación de los picos diarios pudiendo contribuir para el confort y para la disminución de los costos energéticos a él asociados. Puede también XXXVII tener un efecto a largo plazo traducido en alteraciones de las medias mensuales en los meses de inicio y de fin de ciclos estacionales, de variación de la humedad relativa. Estos son los fundamentos que han llevado al desarrollo de soluciones de revestimientos continuos interiores con características de barrera de vapor e higroscopicidad. ESTUDIO EXPERIMENTAL El estudio experimental consta de dos partes: - permeabilidad al vapor e capacidad higroscópica de materiales y productos - adherencia de revestimientos predosificados de yeso a capas impermeables al vapor. 1- Materiales y métodos I. Permeabilidad al vapor y capacidad higroscópica de materiales y productos El desarrollo de esta solución de revestimiento ha comenzado por el estudio de las características de permeabilidad al vapor y de capacidad higroscópica de los materiales y productos utilizados en los revestimientos continuos de cerramientos. Los primeros ensayos han sido realizados en el periodo de docencia del Curso de Doctorado en la asignatura de Aplicaciones Actuales de Conglomerantes Tradicionales, del Profesor Luis de Villanueva Domínguez, y han permitido el primer contacto con los métodos de ensayos y el conocimiento de las normas aplicables. En el trabajo de investigación realizado en la asignatura, se ha ensayado la permeabilidad al vapor e la capacidad higroscópica de morteros de revestimiento, de conglomerantes tradicionales Los materiales y productos ensayados, en ese primer trabajo experimental, han sido, mortero de escayola y cal aérea, yeso de proyectar, mortero de cal aérea y arena, mortero de cal hidráulica y arena, mortero de cemento y arena, mortero de cemento y arena con aditivos impermeabilizantes y morteros impermeabilizantes a base de cemento. En el periodo de investigación del Curso de Doctorado han sido ensayados otros materiales y productos. También con la orientación del Catedrático Luis de Villanueva Domínguez se ha desarrollado el Trabajo Tutelado en el cual se han ensayado materiales y productos de revestimiento continuo de conglomerantes no tradicionales, yesos puros con adiciones naturales, yesos de proyectar con adiciones sintéticas y capas peliculares de diferente origen. De los productos de origen sintético se ha ensayado la permeabilidad al vapor y capacidad higroscópica de estucos acrílicos de relleno (Matesica), estucos acrílicos de acabado (Matesica), mortero sintético de relleno/acabado para exterior o interior (Matesica), mortero sintético de acabado para exterior (Weber), mortero epoxi de relleno y acabado para interior (Gobbetto), morteros de agarre (BASF y Matesica), mortero de reparación de cemento (Weber), mortero de reparación de yeso (Weber). Se ha ensayado también la permeabilidad al vapor de capas peliculares continuas de diferentes orígenes, como aceite de linaza hervido, cera de abeja diluida en esencia de trementina, emulsión bituminosa (Shell), emulsión bituminosa con polímero (BASF), imprimación epoxídica con cemento (BASF), pintura epoxídica (Matesica), pintura anticarbonatación (BASF), estuco Veneciano de cal (La Calce de la Brenta), estuco Veneciano sintético (Gobbetto) e impermeabilización líquida (Weber). Han sido ensayadas también la permeabilidad al vapor y la capacidad higroscópica de yesos puros (portugueses) sin adiciones y con aditivos naturales (cal aérea hidratada 1/1, cola de pescado y cola de conejo). Los yesos de proyectar han sido ensayados sin adiciones y con adiciones de látex SBR (BASF), acrílico (Weber) y epoxi (Matesica). II Adherencia de revestimientos predosificados de yeso a capas impermeables al vapor Como ya se ha dicho anteriormente, hasta una humedad relativa por debajo del 95%, el revestimiento de yeso tiene una capacidad higroscópica inferior al revoco de cemento y al revestimiento acrílico de acabado. Se ha elegido, de acuerdo con el profesor Luis de Villanueva Domínguez, este producto como capa higroscópica del esquema de revestimiento. Las cuestiones de tradición cultural, de abundancia de materia prima en la Península Ibérica, esencialmente en España, y los menores costos energéticos asociados a su fabricación, determinan el origen de esta decisión. Para la producción de 1 m3 de XXXIX cemento son necesarios 12600 MJ, mientras que para 1 m3 de yeso son necesarios solamente 2640 MJ. Pero el yeso presenta otras características mejores que los morteros de cemento, como la menor densidad, menor conductividad térmica y menor efusividad térmica. La mejor capacidad de absorción de agua en la fase líquida por capilaridad, que el mortero de cemento, es otra de las ventajas de los revestimientos de yeso que en situaciones de condensación superficial interior puede evitar el goteo. El paso siguiente ha sido ensayar la adherencia de un revestimiento predosificado de yeso a las capas que han presentado característica de barrera de vapor con espesores hasta 6 mm, así como en aquellas en que los fabricantes recomiendan menores espesores, como el mortero epoxi de relleno y acabado y el mortero sintético de acabado. Se ha utilizado un revestimiento de yeso predosificado de aplicación manual, portugués. La elección de un producto de aplicación manual se ha debido a la dificultad de obtener la aplicación por proyección en el local donde se han hecho las muestras, el taller de la Faculdade de Arquitectura da Universidade Técnica de Lisboa. Se ha aplicado con espesor de 2 cm sobre las capas de aceite de linaza hervido, emulsión de bituminosa, imprimación epoxídica con cemento, pintura epoxídica, impermeabilización líquida, mortero epoxi de relleno y acabado, mortero sintético de acabado. Verificando que ninguno de los materiales que han presentado características de barrera de vapor hasta espesores de 0,6 mm proporcionaban una adherencia al revestimiento de yeso capaz de garantizar el cumplimento de todas las exigencias, se ha decidido elegir los materiales impermeables al vapor más finos y con diferentes orígenes para desarrollar los estudios de mejora de la adherencia. Ha sido necesario desarrollar un conjunto de experimentos con el objetivo de incrementar la adherencia del revestimiento de yeso a estos soportes no absorbentes. La adherencia de los revestimientos continuos de conglomerantes tradicionales, como el yeso sobre soportes absorbentes, se basa en una adherencia mecánica. En este caso los cristales de yeso se van a formar dentro de la red capilar del ladrillo cerámico o del hormigón. Aplicando una barrera de vapor sobre ellos, se elimina esta posibilidad por aplicarse una barrera entre la estructura porosa del soporte (ladrillo u hormigón) y el revestimiento de yeso. Se tiene que producir otro tipo de adherencia, la adherencia química. Esta adherencia se basa en los enlaces químicos, de tipo secundario, como los puentes de hidrógeno o las fuerzas bipolares de Van der Waals. Aunque este tipo de adherencia es menor que la que se produce sobre soportes absorbentes, puede alcanzar valores considerables. Los materiales impermeables al vapor elegidos han sido el aceite de linaza hervido, la emulsión bituminosa y la imprimación epoxi con cemento. A estos materiales de origen natural, artificial e sintético, han sido aplicadas capas intermedias de arena de sílice, mortero de cemento y arena, mortero de agarre y un puente de adherencia de acuerdo con las recomendaciones de Eurogypsum. La capa de arena ha sido aplicada con la última mano aún fresca, mientras que las otras capas intermedias han sido aplicadas con las capas impermeables al vapor ya secas. Las capas intermedias aplicadas han sido: - al aceite de linaza hervido - arena de sílice y puente de adherencia. - a la emulsión bituminosa - arena de sílice, mortero de cemento y arena 1:1 y puente de adherencia - a la capa de imprimación epoxídica con cemento - arena de sílice, mortero de agarre y puente de adherencia. El revestimiento de yeso utilizado ha sido un yeso predosificado de aplicación manual, de origen español, y se ha aplicado con un espesor de 2 centímetros. Para la capa intermedia de puente de adherencia y siguiendo la recomendación del fabricante, se ha añadido un látex de SBR (con relación látex/agua de 1/2) al revestimiento de yeso. Otra experimentación realizada ha sido la adición del látex SBR al revestimiento de yeso y su aplicación directamente sobre cada una de las capas impermeables al vapor, y a cada una de las capas intermedias aplicadas sobre las capas impermeables al vapor. XLI La aplicación del látex en las proporciones de 1/2, de relación látex/agua, puede cambiar algunas propiedades del revestimiento de yeso en pasta, en relación a su aplicación, o tiempo de inicio o fin de fraguado, e incluso tener influencia en el costo final del revestimiento. Puesto que la adherencia del revestimiento de yeso con adición del látex a la capa intermedia de puente de adherencia ha sido muy superior a las exigencias más estrictas, se ha realizado un ensayo, pero sin la adición del látex. Este ensayo se ha realizado aplicando el revestimiento de yeso sobre las capas de puente de adherencia anteriormente aplicadas sobre las capas impermeables al vapor, descritas con anterioridad. Se ha aplicado ahora un revestimiento de yeso predosificado también de aplicación manual, pero de origen portugués. Para garantizar el cumplimiento integral de la exigencia de adherencia de 0,5 MPa, se ha hecho otro ensayo con una menor adición de látex de SBR al yeso predosificado. Se ha aplicado el látex con una relación látex/agua de 1/3 y 1/4. 2 Resultados y discusión I. Permeabilidad al vapor y capacidad higroscópica de materiales y productos En el primer ensayo de permeabilidad al vapor se concluyó que ninguno de los productos ensayados puede constituir barrera de vapor en espesores hasta 2 cm. y que lo que ha presentado mayor resistividad al vapor ha sido el mortero impermeabilizante de capa fina. Tendría que tener un espesor próximo a los 14,12 cm para poder constituir barrera de vapor. En los ensayos de capacidad higroscópica, realizados solamente para humedades relativas del 50% y 95% a temperaturas de 23ºC, el mortero de escayola y cal aérea y el yeso de proyectar han presentado una capacidad higroscópica bastante elevada, pero como el secado ha sido realizado a 100º C (lo que no es la temperatura adecuada para los productos a base de yeso por poder éstos sufrir una deshidratación y un cambio en su constitución) los resultados no pueden ser considerados. El mortero de impermeabilización de capa fina también ha presentado una buena capacidad higroscópica, mejor que el mortero de cemento y arena, y éste mejor que el mortero de cal hidráulica y arena, y éste mejor que el mortero de cal aérea y arena. La adición de aditivos impermeabilizantes no ha cambiado significativamente esta característica. Como resultado de los segundos ensayos se ha concluido que existen diferentes materiales y productos que pueden constituir barrera de vapor con diferentes espesores. Los productos estuco acrílico de relleno, estuco sintético de acabado, mortero sintético de acabado para exterior, mortero epoxi de relleno y acabado, han presentado características de barrera de vapor con espesores hasta 2 cm, sin embargo, son espesores superiores a los recomendados por los fabricantes de los productos. De los productos peliculares, han constituido barrera de vapor, el aceite de linaza hervido (con valores muy próximos), la emulsión bituminosa sin polímero, la imprimación epoxídica con cemento, la pintura epoxídica y la impermeabilización líquida. Todos los demás productos ensayados no han presentado esa característica cuando aplicados en tres manos. Los yesos puros con adiciones naturales y los yesos de proyectar con adiciones sintéticas no han presentado características de barrera de vapor en espesores hasta dos centímetros. El mejor resultado ha sido el del yeso puro con adición de cola de pescado, que ha presentado característica de barrera de vapor con espesor de 16,32 cm. En cuanto a la capacidad higroscópica de los materiales y productos, el ensayo ha sido repetido recientemente con las mismas muestras, porque en el ensayo realizado para el Trabajo Tutelado no fue posible una correcta caracterización. En ese ensayo solo se han obtenido los valores de capacidad higroscópica para valores de humedad del 50 % ± 3 a temperatura de 23 ºC ± 2 por no disponerse de los medios necesarios para un estudio más completo. En el ensayo realizado recientemente en el Laboratório Nacional de Engenharia Civil de Portugal (LNEC), se ha utilizado una cámara climática, con control de temperatura y humedad relativa, y se han obtenido los valores de capacidad higroscópica para valores de humedad relativa del 25%, 50%, 75% y 95% a temperatura constante de 23º C. XLIII En ese último ensayo se ha verificado que para humedades relativas del 50 %, los yesos predosificados de aplicación manual, portugueses y españoles, tienen diferentes capacidades higroscópicas. Los yesos españoles han presentado una capacidad higroscópica de 0,2 % y el portugués de 0,05 %. La adición de látex de SRB no ha reducido la capacidad higroscópica del yeso predosificado español. Los valores se han mantenido próximos para las relaciones látex/agua de 1/4, 1/3 y 1/2, con 0,2 %. Para valores de capacidad higroscópica por volumen se ha verificado que la adición de látex incrementa la capacidad higroscópica, estableciéndose que los valores para el yeso español sin látex han sido de 2,2 g/dm3 y para los yesos con adición de látex han sido de cerca de 2,5 g/dm3. Para este valor de humedad relativa otros productos han presentado mayor capacidad higroscópica, como el yeso puro con cola de pescado con 5,1 g/dm3.Para morteros ensayados con espesores de 0,6 cm, el mortero de reparación de yeso ha presentado un valor de capacidad higroscópica de 4,1 g/dm3 y el mortero de agarre (BASF) ha presentado el valor de 4,6 g/dm3. Para valores de humedad relativa del 95 %, la capacidad higroscópica presentada por el yeso predosificado español ha sido de 1 % y por el portugués ha sido de 0,27 %. La adición de látex tampoco aquí ha alterado la capacidad higroscópica. Las pequeñas diferencia registradas pueden deberse al diferente tiempo en que se han realizado los pesajes, por existir ya mucha agua libre. Para valores de capacidad higroscópica por volumen se ha verificado que la adición de látex incrementa la capacidad higroscópica, estableciéndose que los valores para el yeso español sin látex han sido de 10,6 g/dm3 y para los yesos con adición de látex han sido de cerca de 11,60 g/dm3 para látex/agua de 1/4, 13,77 g/dm3 para látex/agua de 1/3 y 12,20 g/dm3 para látex/agua de 1/2. Para este valor de humedad relativa, otros productos han presentado mayor capacidad higroscópica, y superiores al yeso predosificado de aplicación manual español. El yeso predosificado de proyectar con adición de látex acrílico (Weber), con 14,1 g/dm3, el yeso puro con cola de pescado con 17,8 g/dm3, el yeso puro cal aérea hidratada con 18,3 g/dm3. Para los morteros ensayados con espesores de 0,6 cm, el mortero de agarre Matesica con valor 17,7 g/dm3, el mortero de reparación de yeso con valores de 31,2 g/dm3 y el mortero de agarre BASF con valores de 48,8 g/dm3. Este ultimo valor debería ser verificado por haberse podido producir un error en la cantidad de agua suministrada. XLIV II Adherencia de revestimientos predosificados de yeso a capas impermeables al vapor Realizado el ensayo de adherencia del revestimiento de yeso predosificado aplicado sobre las capas que han constituido barrera de vapor con espesor hasta 6 mm, se ha verificado que los valores requeridos por la norma europea EN 13279 de 2005, con valores de adherencia ≥ 0,1 MPa o rotura cohesiva por el soporte, solo no han sido satisfechos por la pintura epoxídica y por el revestimiento sintético de acabado. Todavía los valores de adherencia no han alcanzado los valores exigidos por las exigencias complementarias del Laboratório Nacional de Engenharia de Portugal (LNEC) o las exigencias españolas. Las exigencias del LNEC, determinan una adherencia ≥ 0,5 MPa, o una ruptura cohesiva. Las exigencias españolas determinan que la adherencia debe ser determinada por la rotura del revestimiento. La solución de revestimiento que mejor resultado ha presentado ha sido la del revestimiento predosificado de yeso aplicado sobre la capa de aceite de linaza hervido, con una adherencia de 0,324 MPa. También se ha ensayado la aplicación de una capa intermedia de mortero de agarre entre las capas impermeables al vapor de imprimación epoxídica y pintura epoxídica. Los resultados obtenidos han sido de 0,21 MPa y de 0,25 MPa respectivamente. De los valores obtenidos en el ensayo de adherencia del revestimiento de yeso predosificado a las capas peliculares elegidas que han constituido barrera de vapor cuando aplicadas en tres manos, solo algunas de las soluciones con adición de látex al yeso han cumplido las exigencias más estrictas. Éstas han sido las capas impermeables al vapor constituidas por emulsión bituminosa e imprimación epoxi con cemento. Las capas intermedias de arena de sílice sobre la emulsión bituminosa y sobre la imprimación epoxi también han cumplido. Las capas intermedias de mortero de cemento sobre emulsión bituminosa, y mortero de agarre sobre imprimación epoxi con cemento también han cumplido. El puente de adherencia sobre emulsión bituminosa e imprimación epoxídica con cemento, han presentado valores muy elevados de adherencia del revestimiento de XLV yeso. Los valores obtenidos han sido tres veces superiores a las exigencias más estrictas. Los valores obtenidos en el ensayo de adherencia del revestimiento de yeso predosificado sobre el puente adherencia aplicado sobre las capas peliculares impermeables al vapor han sido muy cercanos a la exigencia del Laboratório Nacional de Engenharia Civil de Portugal. Presentan una media de 0,456 MPa. Los valores más bajos han sido para la solución de capa impermeable al vapor constituida por aceite de linaza hervido, con el valor de 0,418 MPa. El valor más elevado ha sido para la solución de capa impermeable al vapor constituida por imprimación epoxídica con cemento, con el valor de adherencia de 0,484 MPa. Los valores obtenidos con las capas impermeables al vapor constituidas por aceite de linaza hervido han presentado roturas siempre adhesivas, o en su capa, pero con valores muy diferentes. Los valores de mayor adherencia se han producido con las capas de aceite con mayor tiempo de secado. En el ensayo de adherencia del revestimiento de yeso predosificado con adición de látex con relación agua/látex de 1/3 y 1/4, aplicado sobre el puente de adherencia, aplicado sobre la capa de imprimación epoxi se ha verificado que la solución con relación látex/agua de 1/4 ha superado la exigencia de 0,5 MPa en un 50 %. Esto resultado quiere decir que es posible aplicar una relación de látex/agua aún inferior. PRINCIPALES CONCLUSIONES Como principales conclusiones del estudio experimental podemos decir que es posible obtener un revestimiento continuo interior impermeable al vapor e higroscópico. Se pueden obtener con capas impermeables al vapor de aceite de linaza hervido (debidamente seco), emulsión bituminosa o con imprimación epoxídica con cemento, aplicadas directamente sobre el ladrillo. Como capa higroscópica se puede aplicar un revestimiento de yeso predosificado, no obstante sea menos higroscópico que un revestimiento de mortero de cemento y arena (hasta humedades relativas del 95%). La adherencia entre la capa impermeable al vapor y el revestimiento de yeso predosificado, puede conseguirse con un puente de adherencia entre las dos capas anteriormente descritas. Si la adherencia del yeso no fuera capaz de cumplir las exigencias más estrictas (0,5 MPa) puede añadirse un látex de SBR al yeso en una relación de látex agua de 1/4. Esa adición permite una adherencia un 50 % superior a las exigencias más estrictas, por lo que se pueden ensayar relaciones aún menores de L/A. Estas adiciones no restan capacidad higroscópica al revestimiento, pudiendo incluso incrementarla (para humedades relativas del 25% al 95%) con beneficio para la inercia higroscópica del edificio donde fuese aplicado. Con respecto a la influencia de la solución de revestimiento propuesta en el riesgo de condensaciones intersticiales, se puede decir que no ha sido posible observar una diferencia significativa en las simulaciones realizadas, entre la aplicación del revestimiento y su no aplicación. Las simulaciones han sido realizadas con la aplicación informática Wufi 5 Pro, que respeta la normativa más reciente relativa a las condensaciones intersticiales. Comparando con la solución tradicional de aplicación de barrera de vapor en la cámara de aire, tampoco se han verificado grandes diferencias. Cabe destacar que esta solución tradicional no ha presentado diferencias en relación a la no aplicación de barrera de vapor. Estas simulaciones contradicen lo comúnmente establecido hasta ahora, que es considerar que la aplicación de barreras de vapor en la parte caliente del cerramiento reduce considerablemente el riesgo de condensaciones intersticiales. Estas simulaciones han sido realizadas considerando que la fracción de lluvia adherida al cerramiento seria la correspondiente a la solución constructiva y a su inclinación. En la definición del componente pared del cerramiento no existe la posibilidad de colocar la capa de pintura exterior. Considerando la hipótesis de que con la capa de pintura exterior, no existe absorción de agua de lluvia, en esta solución constructiva, los valores obtenidos han cambiado considerablemente. El contenido total de agua en el elemento ha sido menor en la solución con barrera de vapor en el revestimiento (pico máximo de 1 Kg/m2), seguido de la solución de barrera de vapor en la cámara de aire (pico máximo de 1,4 Kg/m2) y esto menor que la solución sin barrera de vapor (pico máximo de 1,8 Kg/m2). El contenido de agua en la lana de roca también ha sido menor en la solución con barrera de vapor en el revestimiento interior (pico máximo de 1,15 %), seguido de la solución con barrera de vapor en la cámara de aire (pico máximo de 1,5 %). y esto menor que la solución sin barrera de vapor (pico máximo de 1,62 %).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Corrosion of steel bars embedded in concrete has a great influence on structural performance and durability of reinforced concrete. Chloride penetration is considered to be a primary cause of concrete deterioration in a vast majority of structures. Therefore, modelling of chloride penetration into concrete has become an area of great interest. The present work focuses on modelling of chloride transport in concrete. The differential macroscopic equations which govern the problem were derived from the equations at the microscopic scale by comparing the porous network with a single equivalent pore whose properties are the same as the average properties of the real porous network. The resulting transport model, which accounts for diffusion, migration, advection, chloride binding and chloride precipitation, consists of three coupled differential equations. The first equation models the transport of chloride ions, while the other two model the flow of the pore water and the heat transfer. In order to calibrate the model, the material parameters to determine experimentally were identified. The differential equations were solved by means of the finite element method. The classical Galerkin method was employed for the pore solution flow and the heat transfer equations, while the streamline upwind Petrov Galerkin method was adopted for the transport equation in order to avoid spatial instabilities for advection dominated problems. The finite element codes are implemented in Matlab® . To retrieve a good understanding of the influence of each variable and parameter, a detailed sensitivity analysis of the model was carried out. In order to determine the diffusive and hygroscopic properties of the studied concretes, as well as their chloride binding capacity, an experimental analysis was performed. The model was successfully compared with experimental data obtained from an offshore oil platform located in Brazil. Moreover, apart from the main objectives, numerous results were obtained throughout this work. For instance, several diffusion coefficients and the relation between them are discussed. It is shown how the electric field set up between the ionic species depends on the gradient of the species’ concentrations. Furthermore, the capillary hysteresis effects are illustrated by a proposed model, which leads to the determination of several microstructure properties, such as the pore size distribution and the tortuosity-connectivity of the porous network. El fenómeno de corrosión del acero de refuerzo embebido en el hormigón ha tenido gran influencia en estructuras de hormigón armado, tanto en su funcionalidad estructural como en aspectos de durabilidad. La penetración de cloruros en el interior del hormigón esta considerada como el factor principal en el deterioro de la gran mayoría de estructuras. Por lo tanto, la modelización numérica de dicho fenómeno ha generado gran interés. El presente trabajo de investigación se centra en la modelización del transporte de cloruros en el interior del hormigón. Las ecuaciones diferenciales que gobiernan los fenómenos a nivel macroscópico se deducen de ecuaciones planteadas a nivel microscópico. Esto se obtiene comparando la red porosa con un poro equivalente, el cual mantiene las mismas propiedades de la red porosa real. El modelo está constituido por tres ecuaciones diferenciales acopladas que consideran el transporte de cloruros, el flujo de la solución de poro y la transferencia de calor. Con estas ecuaciones se tienen en cuenta los fenómenos de difusión, migración, advección, combinación y precipitación de cloruros. El análisis llevado a cabo en este trabajo ha definido los parámetros necesarios para calibrar el modelo. De acuerdo con ellas, se seleccionaron los ensayos experimentales a realizar. Las ecuaciones diferenciales se resolvieron mediante el método de elementos finitos. El método clásico de Galerkin se empleó para solucionar las ecuaciones de flujo de la solución de poro y de la transferencia de calor, mientras que el método streamline upwind Petrov-Galerkin se utilizó para resolver la ecuación de transporte de cloruros con la finalidad de evitar inestabilidades espaciales en problemas con advección dominante. El código de elementos finitos está implementado en Matlab® . Con el objetivo de facilitar la comprensión del grado de influencia de cada variable y parámetro, se realizó un análisis de sensibilidad detallado del modelo. Se llevó a cabo una campaña experimental sobre los hormigones estudiados, con el objeto de obtener sus propiedades difusivas, químicas e higroscópicas. El modelo se contrastó con datos experimentales obtenidos en una plataforma petrolera localizada en Brasil. Las simulaciones numéricas corroboraron los datos experimentales. Además, durante el desarrollo de la investigación se obtuvieron resultados paralelos a los planteados inicialmente. Por ejemplo, el análisis de diferentes coeficientes de difusión y la relación entre ellos. Así como también se observó que el campo eléctrico establecido entre las especies iónicas disueltas en la solución de poro depende del gradiente de concentración de las mismas. Los efectos de histéresis capilar son expresados por el modelo propuesto, el cual conduce a la determinación de una serie de propiedades microscópicas, tales como la distribución del tamaño de poro, además de la tortuosidad y conectividad de la red porosa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El trigo blando (Triticum aestivum ssp vulgare L., AABBDD, 2n=6x=42) presenta propiedades viscoélasticas únicas debidas a la presencia en la harina de las prolaminas: gluteninas y gliadinas. Ambos tipos de proteínas forman parte de la red de gluten. Basándose en la movilidad en SDS-PAGE, las gluteninas se clasifican en dos grupos: gluteninas de alto peso molecular (HMW-GS) y gluteninas de bajo peso molecular (LMW-GS). Los genes que codifican para las HMW-GS se encuentran en tres loci del grupo 1 de cromosomas: Glu-A1, Glu-B1 y Glu-D1. Cada locus codifica para uno o dos polipéptidos o subunidades. La variación alélica de las HMW-GS es el principal determinante de de la calidad harino-panadera y ha sido ampliamente estudiado tanto a nivel de proteína como de ADN. El conocimiento de estas proteínas ha contribuido sustancialmente al progreso de los programas de mejora para la calidad del trigo. Comparadas con las HMW-GS, las LMW-GS forman una familia proteica mucho más compleja. La mayoría de los genes LMW se localizan en el grupo 1 de cromosomas en tres loci: Glu-A3, Glu-B3 y Glu-D3 que se encuentran estrechamente ligados a los loci que codifican para gliadinas. El número de copias de estos genes ha sido estimado entre 10-40 en trigo hexaploide, pero el número exacto aún se desconoce debido a la ausencia de un método eficiente para diferenciar los miembros de esta familia multigénica. La nomenclatura de los alelos LMW-GS por electroforesis convencional es complicada, y diferentes autores asignan distintos alelos a la misma variedad lo que dificulta aún más el estudio de esta compleja familia. El uso de marcadores moleculares para la discriminación de genes LMW, aunque es una tarea dificil, puede ser muy útil para los programas de mejora. El objetivo de este trabajo ha sido profundizar en la relación entre las gluteninas y la calidad panadera y desarrollar marcadores moleculares que permitan ayudar en la correcta clasificación de HMW-GS y LMW-GS. Se han obtenido dos poblaciones de líneas avanzadas F4:6 a partir de los cruzamientos entre las variedades ‘Tigre’ x ‘Gazul’ y ‘Fiel’ x ‘Taber’, seleccionándose para los análisis de calidad las líneas homogéneas para HMW-GS, LMW-GS y gliadinas. La determinación alélica de HMW-GS se llevó a cabo por SDS-PAGE, y se complementó con análisis moleculares, desarrollándose un nuevo marcador de PCR para diferenciar entre las subunidades Bx7 y Bx7*del locus Glu-B1. Resumen 2 La determinación alélica para LMW-GS se llevó a cabo mediante SDS-PAGE siguiendo distintas nomenclaturas y utilizando variedades testigo para cada alelo. El resultado no fue concluyente para el locus Glu-B3, así que se recurrió a marcadores moleculares. El ADN de los parentales y de los testigos se amplificó usando cebadores diseñados en regiones conservadas de los genes LMW y fue posteriormente analizado mediante electroforesis capilar. Los patrones de amplificación obtenidos fueron comparados entre las distintas muestras y permitieron establecer una relación con los alelos de LMW-GS. Con este método se pudo aclarar la determinación alélica de este locus para los cuatro parentales La calidad de la harina fue testada mediante porcentaje de contenido en proteína, prueba de sedimentación (SDSS) y alveógrafo de Chopin (parámetros P, L, P/L y W). Los valores fueron analizados en relación a la composición en gluteninas. Las líneas del cruzamiento ‘Fiel’ x ‘Taber’ mostraron una clara influencia del locus Glu-A3 en la variación de los valores de SDSS. Las líneas que llevaban el nuevo alelo Glu-A3b’ presentaron valores significativamente mayores que los de las líneas con el alelo Glu-A3f. En las líneas procedentes del cruzamiento ‘Tigre ’x ‘Gazul’, los loci Glu-B1 y Glu-B3 loci mostraron ambos influencia en los parámetros de calidad. Los resultados indicaron que: para los valores de SDSS y P, las líneas con las HMW-GS Bx7OE+By8 fueron significativamente mejores que las líneas con Bx17+By18; y las líneas que llevaban el alelo Glu-B3ac presentaban valores de P significativamente superiores que las líneas con el alelo Glu-B3ad y significativamente menores para los valores de L . El análisis de los valores de calidad en relación a los fragmentos LMW amplificados, reveló un efecto significativo entre dos fragmentos (2-616 y 2-636) con los valores de P. La presencia del fragmento 2-636 estaba asociada a valores de P mayores. Estos fragmentos fueron clonados y secuenciados, confirmándose que correspondían a genes del locus Glu-B3. El estudio de la secuencia reveló que la diferencia entre ambos se hallaba en algunos SNPs y en una deleción de 21 nucleótidos que en la proteína correspondería a un InDel de un heptapéptido en la región repetida de la proteína. En este trabajo, la utilización de líneas que difieren en el locus Glu-B3 ha permitido el análisis de la influencia de este locus (el peor caracterizado hasta la fecha) en la calidad panadera. Además, se ha validado el uso de marcadores moleculares en la determinación alélica de las LMW-GS y su relación con la calidad panadera. Summary 3 Bread wheat (Triticum aestivum ssp vulgare L., AABBDD, 2n=6x=42) flour has unique dough viscoelastic properties conferred by prolamins: glutenins and gliadins. Both types of proteins are cross-linked to form gluten polymers. On the basis of their mobility in SDS-PAGE, glutenins can be classified in two groups: high molecular weight glutenins (HMW-GS) and low molecular weight glutenins (LMW-GS). Genes encoding HMW-GS are located on group 1 chromosomes in three loci: Glu-A1, Glu-B1 and Glu-D1, each one encoding two polypeptides, named subunits. Allelic variation of HMW-GS is the most important determinant for bread making quality, and has been exhaustively studied at protein and DNA level. The knowledge of these proteins has substantially contributed to genetic improvement of bread quality in breeding programs. Compared to HMW-GS, LMW-GS are a much more complex family. Most genes encoded LMW-GS are located on group 1 chromosomes. Glu-A3, Glu-B3 and Glu-D3 loci are closely linked to the gliadin loci. The total gene copy number has been estimated to vary from 10–40 in hexaploid wheat. However, the exact copy number of LMW-GS genes is still unknown, mostly due to lack of efficient methods to distinguish members of this multigene family. Nomenclature of LMW-GS alleles is also unclear, and different authors can assign different alleles to the same variety increasing confusion in the study of this complex family. The use of molecular markers for the discrimination of LMW-GS genes might be very useful in breeding programs, but their wide application is not easy. The objective of this work is to gain insight into the relationship between glutenins and bread quality, and the developing of molecular markers that help in the allele classification of HMW-GS and LMW-GS. Two populations of advanced lines F4:6 were obtained from the cross ‘Tigre’ x ‘Gazul’ and ‘Fiel’ x ‘Taber’. Lines homogeneous for HMW-GS, LMW-GS and gliadins pattern were selected for quality analysis. The allele classification of HMW-GS was performed by SDS-PAGE, and then complemented by PCR analysis. A new PCR marker was developed to undoubtedly differentiate between two similar subunits from Glu-B1 locus, Bx7 and Bx7*. The allele classification of LMW-GS was initially performed by SDS-PAGE following different established nomenclatures and using standard varieties. The results were not completely concluding for Glu-B3 locus, so a molecular marker system was applied. DNA from parental lines and standard varieties was amplified using primers designed in conserved domains of LMW genes and analyzed by capillary electrophoresis. The pattern of amplification products obtained was compared among samples and related to the protein allele classification. It was possible to establish a correspondence between specific amplification products and almost all LMW alleles analyzed. With this method, the allele classification of the four parental lines was clarified. Flour quality of F4:6 advanced lines were tested by protein content, sedimentation test (SDSS) and alveograph (P, L, P/L and W). The values were analyzed in relation to the lines prolamin composition. In the ‘Fiel’ x ‘Taber’ population, Glu-A3 locus showed an influence in SDSS values. Lines carrying new allele Glu-A3b’, presented a significantly higher SDSS value than lines with Glu-A3f allele. In the ‘Tigre ’x ‘Gazul’ population, the Glu-B1 and Glu-B3 loci also showed an effect in quality parameters, in SDSS, and P and L values. Results indicated that: for SDSS and P, lines with Bx7OE+By8 were significantly better than lines with Bx17+By18; lines carrying Glu-B3ac allele had a significantly higher P values than Glu-B3ad allele values. lines with and lower L The analysis of quality parameters and amplified LMW fragments revealed a significant influence of two peaks (2-616 y 2-636) in P values. The presence of 2-636 peak gave higher P values than 2-616. These fragments had been cloned and sequenced and identified as Glu-B3 genes. The sequence analysis revealed that the molecular difference between them was some SNPs and a small deletion of 21 nucleotides that in the protein would produce an InDel of a heptapeptide in the repetitive region. In this work, the analysis of two crosses with differences in Glu-3 composition has made possible to study the influence of LMG-GS in quality parameters. Specifically, the influence of Glu-B3, the most interesting and less studied loci has been possible. The results have shown that Glu-B3 allele composition influences the alveograph parameter P (tenacity). The existence of different molecular variants of Glu-B3 alleles have been assessed by using a molecular marker method. This work supports the use of molecular approaches in the study of the very complex LMW-GS family, and validates their application in the analysis of advanced recombinant lines for quality studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El deterioro del hormigón debido a la presencia del ion cloruro es causa frecuente de problemas en estructuras localizadas en ambiente marino y alta montaña. Su principal efecto consiste en la despasivación del acero de refuerzo embebido en el hormigón y su consecuente inicio de la corrosión del mismo. El ingreso del ion cloruro al interior del hormigón, está condicionado por una serie de parámetros de origen medioambiental e intrínsecos del hormigón. En función de estos parámetros el ingreso de cloruros en el hormigón puede deberse principalmente a los siguientes mecanismos: difusión y succión capilar. El estudio y evaluación de la resistencia del hormigón frente a cloruros, se ha desarrollado principalmente en condiciones saturadas del hormigón. Lo que ha significado que parámetros de importancia no sean considerados. Debido a esto, distintos procesos que suceden en estructuras reales no han sido identificados y estudiados correctamente. En este trabajo, se diseñó un programa de investigación para evaluar los parámetros que influyen en el transporte cloruros en hormigones no saturados. Para esto se diseñaron tres dosificaciones diferentes de hormigón. En la primera se empleó únicamente cemento portland, para el resto se utilizaron adiciones minerales (humo de sílice y escoria de alto horno). El empleo de adiciones se debió a que tienen un papel importante en la durabilidad de hormigones frente a cloruros. Los hormigones fueron dosificados con una relación agua/material cementício de 0,40 para el hormigón elaborado únicamente con cemento portland y 0,45 para las mezclas con adiciones. Para evaluar las propiedades de los hormigones en estado fresco y endurecido se realizaron ensayos vigentes en las normativas. Con los resultados obtenidos se determinaron parámetros de resistencia mecánica, microestructurales, resistencia al transporte de cloruros e higroscópicos. Una vez caracterizados los hormigones, se diseñó una propuesta experimental para estudiar los principales parámetros presentes en estructuras reales con presencia de cloruros. Tanto la concentración de cloruro como las condiciones ambientales se han variado teniendo como referencia las situaciones reales que podrían producirse en ambientes de alta montaña en la zona centro de España. La propuesta experimental consistió en tratar de evaluar la capacidad de los hormigones al transporte de iones en ambientes de alta montaña con presencia de sales fundentes. Para esto se establecieron 5 fases experimentales donde los principales parámetros ambientales y la presencia de iones agresivos sufrieron variaciones. Al término de cada fase se obtuvieron perfiles de penetración de cloruros en los hormigones y se evaluó la influencia de los parámetros presentes en cada fase. Los resultados experimentales se implementaron en un modelo numérico basado en la teoría de elementos finitos, desarrollado por el grupo de investigación del Departamento de Materiales de Construcción. Para esto fue necesario realizar la calibración y validación del modelo numérico para cada hormigón. El calibrado del modelo precisa de datos químicos y microestructurales de cada hormigón, tales como: capacidad de combinación de cloruros y propiedades difusivas e higroscópicas. Para la validación del modelo numérico se realizaron simulaciones de la propuesta experimental. Los resultados obtenidos se compararon con los valores experimentales. Con el objeto de poder estudiar en mayor profundidad la influencia del grado de saturación del hormigón durante la difusión de cloruros, se llevó a cabo una campaña experimental que consideró distintos grados de saturación en los hormigones. Para esto se establecieron en los hormigones cuatro grados de saturación distintos (50%, 60%, 80% y 100%, aproximadamente), posteriormente se expusieron a cloruro de sodio finamente molido. Una vez transcurrido el tiempo necesario se obtuvieron experimentalmente los perfiles de penetración de cloruros para cada grado de saturación y se calcularon los coeficientes de difusión. Los datos obtenidos durante la campaña experimental han demostrado la influencia positiva que ejercen las adiciones en las mezclas de hormigón. Sus principales ventajas son el refinamiento de la red porosa y el aumento en la capacidad de combinación de cloruros, además de mejorar sus propiedades mecánicas. La porosidad total en las mezclas no presentó grandes cambios, sin embargo, el cambio en la distribución del tamaño de poros es importante en las muestras con adiciones. En especial las fabricadas con humo de sílice. Los coeficientes de difusión y migración de cloruros para las mezclas con adiciones disminuyeron significativamente, igual que los valores de resistividad eléctrica. En los ensayos de penetración del agua bajo presión, fueron las muestras con adiciones las que mostraron las menores penetraciones. Los resultados obtenidos al final de la propuesta experimental permitieron estudiar los distintos parámetros involucrados. Se observó claramente que el proceso de difusión provoca el mayor transporte de cloruros hacia el interior del hormigón. Así mismo se comprobó que el lavado superficial y el secado de las probetas, trasladan cloruros hacia las zonas externas del hormigón. El primero debido a una baja concentración de cloruros externa, mientras que el secado provoca el movimiento de la solución de poro hacia las zonas de secado depositando cloruros en ellas. Las medidas higroscópicas permitieron determinar la existencia de dos zonas distintas en el interior del hormigón. La primera se localizó en el rango de 0-10mm, aproximadamente, en ésta se puso de manifiesto una mayor sensibilidad a los cambios experimentados en el exterior de las probetas. La segunda zona se localizó a una profundidad mayor de 10mm, aproximadamente. Se observó claramente una baja influencia de los cambios externos, siendo la difusión de cloruros el principal mecanismo de transporte presente en ella. En cuanto al estudio de la influencia del grado de saturación en la difusión de cloruros, se observó claramente una marcada diferencia entre los coeficientes de difusión de cloruro obtenidos. Para grados de saturación mayores del 80% el mecanismo de penetración de cloruros por difusión existe de forma significativa. Mientras que para valores inferiores los resultados revelaron que las vías de acceso disminuyen (poros conectado con agua) considerablemente limitando en un alto grado la penetración del agresivo. Para grados de saturación inferiores del 50% los valores del coeficiente de difusión son despreciables. The deterioration of concrete due to chloride ions is a frequent problem identified in structures located in marine and high-mountain environments. After entering the outer layer of the concrete, the chlorides tend to penetrate until they reach and then depassivate the steel bars. Subsequently, this induces the deterioration process of the reinforced concrete. This chloride penetration depends on the environmental conditions and intrinsic parameters of the concrete. Several transport mechanisms, such as diffusion, capillary suction and permeability can be present into the concrete. While recent research into the study and evaluation of concretes with chloride presence has been carried out in saturated concrete, it has not considered certain parameters that can modify this condition. Consequently, at the time of writing several processes that take place in real structures have not been identified and studied. In this work a research programme is designed to evaluate the parameters that influence chloride transport into non-saturated concrete. For this, three concrete mixes were designed by using high-early-strength Portland cement and mineral admixtures (silica fume and blast-slag furnace). The water-cement ratio was 0.40 for the concrete made solely with Portland cement and 0.45 for the concretes that used mineral admixtures as a cement replacement. A set of experimental tests were performed to evaluate the concrete properties both in fresh and hardened state. In addition, an experimental simulation was carried out under laboratory conditions in which the main objective was to assess resistance of concrete to chloride penetration under high-mountain conditions with the presence of de-icing salts. The environmental conditions and surface chloride concentration of the concrete used during the experimental simulation were chosen by considering conditions found in the high-mountain environment in central Spain. For the experimental simulation five phases were designed by varying the environmental parameters and concrete surface concentration. At the end of each phase a chloride profile was obtained with the aim of assessing the influence of the parameters on chloride transport. The experimental results were then used to calibrate and validate a numerical model based on finite element theory developed by the research team from the Construction Materials Department in a previous work. In order to carry out model calibration chemical and microstructural data for the concretes was required, such as binding capacity and the diffusive and hygroscopic properties. The experimental results were compared with the numerical simulations and provided a good fit. With the objective of studying the influence of the degree of concrete saturation on chloride diffusion, an experimental programme was designed. This entailed four saturation degrees (50%, 60%, 80% and 100%) being established in several concrete samples. The samples were then exposed to ground sodium chloride. Once the time required was achieved, the chloride profiles and diffusion coefficients were obtained for each saturation degree. The results obtained from the experimental program revealed a positive influence of the mineral admixtures on the concretes. Their effects were reflected in the pore-network refinement and the increase of chloride binding capacity, together with the improvement of the mechanical properties of the concretes. Total porosity did not reveal any notable change, though the pore-size distribution showed a significant degree of change in the concretes with mineral admixtures, specifically the samples prepared through use of silica fume. The chloride diffusion and migration coefficient, as well as the electrical resistivity values, decreased significantly in the concretes with admixtures. In the water penetration under pressure test, the concretes with admixtures presented the lowest penetration depth. The results obtained in the experimental simulation allowed study of the main parameters involved during the chloride penetration processes in non-saturated concretes in the presence of chlorides. According to the results, the diffusion process was the transport mechanism that transferred the greatest amount of chlorides into the concrete samples. In addition, a chloride movement toward external zones of the concrete, caused by the washing of concrete surface and the drying processes, was identified. The washing occurred when the concrete surface came into contact with a low-chloride concentration solution which initiated the outward movement of chloride diffusion. The drying processes corresponded to a movement of pore solution launched by water evaporation from the outer layer. Furthermore, hygroscopic measurements made in the concrete allowed two areas with distinct behavioural patterns to be identified. The first one, located in the range of approximately 0-10mm, showed a greater degree of influence regarding the changes of the external conditions. The second, situated at depths greater than 10mm, displayed a low influence of external conditions. The main process in this area was diffusion. Study of the influence of the degree of concrete saturation on chloride diffusion showed a clear difference among the chloride diffusion coefficients obtained. For degrees of concrete saturation higher than 80%, chloride penetration by diffusion tends to be significant. However, in the case of extent of saturation of lower than 80%, the results revealed that the access zone through which chlorides can penetrate decreased considerably. For degrees of concrete saturation lower than 50%, the chloride diffusion coefficients were negligible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El auge que ha surgido en los últimos años por la reparación de edificios y estructuras construidas con hormigón ha llevado al desarrollo de morteros de reparación cada vez más tecnológicos. En el desarrollo de estos morteros por parte de los fabricantes, surge la disyuntiva en el uso de los polímeros en sus formulaciones, por no encontrarse justificado en ocasiones el trinomio prestaciones/precio/aplicación. En esta tesis se ha realizado un estudio exhaustivo para la justificación de la utilización de estos morteros como morteros de reparación estructural como respuesta a la demanda actual disponiéndolo en tres partes: En la primera parte se realizó un estudio del arte de los morteros y sus constituyentes. El uso de los morteros se remonta a la antigüedad, utilizándose como componentes yeso y cal fundamentalmente. Los griegos y romanos desarrollaron el concepto de morteros de cal, introduciendo componentes como las puzolanas, cales hidraúlicas y áridos de polvo de mármol dando origen a morteros muy parecidos a los hormigones actuales. En la edad media y renacimiento se perdió la tecnología desarrollada por los romanos debido al extenso uso de la piedra en las construcciones civiles, defensivas y religiosas. Hubo que esperar hasta el siglo XIX para que J. Aspdin descubriese el actual cemento como el principal compuesto hidraúlico. Por último y ya en el siglo XX con la aparición de moléculas tales como estireno, melanina, cloruro de vinilo y poliésteres se comenzó a desarrollar la industria de los polímeros que se añadieron a los morteros dando lugar a los “composites”. El uso de polímeros en matrices cementantes dotan al mortero de propiedades tales como: adherencia, flexibilidad y trabajabilidad, como ya se tiene constancia desde los años 30 con el uso de caucho naturales. En la actualidad el uso de polímeros de síntesis (polivinialacetato, estireno-butadieno, viniacrílico y resinas epoxi) hacen que principalmente el mortero tenga mayor resistencia al ataque del agua y por lo tanto aumente su durabilidad ya que se minimizan todas las reacciones de deterioro (hielo, humedad, ataque biológico,…). En el presente estudio el polímero que se utilizó fue en estado polvo: polímero redispersable. Estos polímeros están encapsulados y cuando se ponen en contacto con el agua se liberan de la cápsula formando de nuevo el gel. En los morteros de reparación el único compuesto hidraúlico que hay es el cemento y es el principal constituyente hoy en día de los materiales de construcción. El cemento se obtiene por molienda conjunta de Clínker y yeso. El Clínker se obtiene por cocción de una mezcla de arcillas y calizas hasta una temperatura de 1450-1500º C por reacción en estado fundente. Para esta reacción se deben premachacar y homogeneizar las materias primas extraídas de la cantera. Son dosificadas en el horno con unas proporciones tales que cumplan con unas relación de óxidos tales que permitan formar las fases anhidras del Clínker C3S, C2S, C3A y C4AF. De la hidratación de las fases se obtiene el gel CSH que es el que proporciona al cemento de sus propiedades. Existe una norma (UNE-EN 197-1) que establece la composición, especificaciones y tipos de cementos que se fabrican en España. La tendencia actual en la fabricación del cemento pasa por el uso de cementos con mayores contenidos de adiciones (cal, puzolana, cenizas volantes, humo de sílice,…) con el objeto de obtener cementos más sostenibles. Otros componentes que influyen en las características de los morteros son: - Áridos. En el desarrollo de los morteros se suelen usar naturales, bien calizos o silícicos. Hacen la función de relleno y de cohesionantes de la matriz cementante. Deben ser inertes - Aditivos. Son aquellos componentes del mortero que son dosificados en una proporción menor al 5%. Los más usados son los superplastificantes por su acción de reductores de agua que revierte en una mayor durabilidad del mortero. Una vez analizada la composición de los morteros, la mejora tecnológica de los mismos está orientada al aumento de la durabilidad de su vida en obra. La durabilidad se define como la capacidad que éste tiene de resistir a la acción del ambiente, ataques químicos, físicos, biológicos o cualquier proceso que tienda a su destrucción. Estos procesos dependen de factores tales como la porosidad del hormigón y de la exposición al ambiente. En cuanto a la porosidad hay que tener en cuenta la distribución de macroporos, mesoporos y microporos de la estructura del hormigón, ya que no todos son susceptibles de que se produzca el transporte de agentes deteriorantes, provocando tensiones internas en las paredes de los mismos y destruyendo la matriz cementante Por otro lado los procesos de deterioro están relacionados con la acción del agua bien como agente directo o como vehículo de transporte del agente deteriorante. Un ambiente que resulta muy agresivo para los hormigones es el marino. En este caso los procesos de deterioro están relacionados con la presencia de cloruros y de sulfatos tanto en el agua de mar como en la atmosfera que en combinación con el CO2 y O2 forman la sal de Friedel. El deterioro de las estructuras en ambientes marinos se produce por la debilitación de la matriz cementante y posterior corrosión de las armaduras que provocan un aumento de volumen en el interior y rotura de la matriz cementante por tensiones capilares. Otras reacciones que pueden producir estos efectos son árido-álcali y difusión de iones cloruro. La durabilidad de un hormigón también depende del tipo de cemento y su composición química (cementos con altos contenidos de adición son más resistentes), relación agua/cemento y contenido de cemento. La Norma UNE-EN 1504 que consta de 10 partes, define los productos para la protección y reparación de estructuras de hormigón, el control de calidad de los productos, propiedades físico-químicas y durables que deben cumplir. En esta Norma se referencian otras 65 normas que ofrecen los métodos de ensayo para la evaluación de los sistemas de reparación. En la segunda parte de esta Tesis se hizo un diseño de experimentos con diferentes morteros poliméricos (con concentraciones de polímero entre 0 y 25%), tomando como referencia un mortero control sin polímero, y se estudiaron sus propiedades físico-químicas, mecánicas y durables. Para mortero con baja proporción de polímero se recurre a sistemas monocomponentes y para concentraciones altas bicomponentes en la que el polímero está en dispersión acuosa. Las propiedades mecánicas medidas fueron: resistencia a compresión, resistencia a flexión, módulo de elasticidad, adherencia por tracción directa y expansión-retracción, todas ellas bajo normas UNE. Como ensayos de caracterización de la durabilidad: absorción capilar, resistencia a carbonatación y adherencia a tracción después de ciclos hielo-deshielo. El objeto de este estudio es seleccionar el mortero con mejor resultado general para posteriormente hacer una comparativa entre un mortero con polímero (cantidad optimizada) y un mortero sin polímero. Para seleccionar esa cantidad óptima de polímero a usar se han tenido en cuenta los siguientes criterios: el mortero debe tener una clasificación R4 en cuanto a prestaciones mecánicas al igual que para evaluar sus propiedades durables frente a los ciclos realizados, siempre teniendo en cuenta que la adición de polímero no puede ser elevada para hacer el mortero competitivo. De este estudio se obtuvieron las siguientes conclusiones generales: - Un mortero normalizado no cumple con propiedades para ser clasificado como R3 o R4. - Sin necesidad de polímero se puede obtener un mortero que cumpliría con R4 para gran parte de las características medidas - Es necesario usar relaciones a:c< 0.5 para conseguir morteros R4, - La adición de polímero mejora siempre la adherencia, abrasión, absorción capilar y resistencia a carbonatación - Las diferentes proporciones de polímero usadas siempre suponen una mejora tecnológica en propiedades mecánicas y de durabilidad. - El polímero no influye sobre la expansión y retracción del mortero. - La adherencia se mejora notablemente con el uso del polímero. - La presencia de polímero en los morteros mejoran las propiedades relacionadas con la acción del agua, por aumento del poder cementante y por lo tanto de la cohesión. El poder cementante disminuye la porosidad. Como consecuencia final de este estudio se determinó que la cantidad óptima de polímero para la segunda parte del estudio es 2.0-3.5%. La tercera parte consistió en el estudio comparativo de dos morteros: uno sin polímero (mortero A) y otro con la cantidad optimizada de polímero, concluida en la parte anterior (mortero B). Una vez definido el porcentaje de polímeros que mejor se adapta a los resultados, se plantea un nuevo esqueleto granular mejorado, tomando una nueva dosificación de tamaños de áridos, tanto para el mortero de referencia, como para el mortero con polímeros, y se procede a realizar los ensayos para su caracterización física, microestructural y de durabilidad, realizándose, además de los ensayos de la parte 1, mediciones de las propiedades microestructurales que se estudiaron a través de las técnicas de porosimetría de mercurio y microscopia electrónica de barrido (SEM); así como propiedades del mortero en estado fresco (consistencia, contenido de aire ocluido y tiempo final de fraguado). El uso del polímero frente a la no incorporación en la formulación del mortero, proporcionó al mismo de las siguientes ventajas: - Respecto a sus propiedades en estado fresco: El mortero B presentó mayor consistencia y menor cantidad de aire ocluido lo cual hace un mortero más trabajable y más dúctil al igual que más resistente porque al endurecer dejará menos huecos en su estructura interna y aumentará su durabilidad. Al tener también mayor tiempo de fraguado, pero no excesivo permite que la manejabilidad para puesta en obra sea mayor, - Respecto a sus propiedades mecánicas: Destacar la mejora en la adherencia. Es una de las principales propiedades que confiere el polímero a los morteros. Esta mayor adherencia revierte en una mejora de la adherencia al soporte, minimización de las posibles reacciones en la interfase hormigón-mortero y por lo tanto un aumento en la durabilidad de la reparación ejecutada con el mortero y por consecuencia del hormigón. - Respecto a propiedades microestructurales: la porosidad del mortero con polímero es menor y menor tamaño de poro critico susceptible de ser atacado por agentes externos causantes de deterioro. De los datos obtenidos por SEM no se observaron grandes diferencias - En cuanto a abrasión y absorción capilar el mortero B presentó mejor comportamiento como consecuencia de su menor porosidad y su estructura microscópica. - Por último el comportamiento frente al ataque de sulfatos y agua de mar, así como al frente de carbonatación, fue más resistente en el mortero con polímero por su menor permeabilidad y su menor porosidad. Para completar el estudio de esta tesis, y debido a la gran importancia que están tomando en la actualidad factores como la sostenibilidad se ha realizado un análisis de ciclo de vida de los dos morteros objeto de estudio de la segunda parte experimental.In recent years, the extended use of repair materials for buildings and structures made the development of repair mortars more and more technical. In the development of these mortars by producers, the use of polymers in the formulations is a key point, because sometimes this use is not justified when looking to the performance/price/application as a whole. This thesis is an exhaustive study to justify the use of these mortars as a response to the current growing demand for structural repair. The thesis is classified in three parts:The first part is the study of the state of the art of mortars and their constituents.In ancient times, widely used mortars were based on lime and gypsum. The Greeks and Romans developed the concept of lime mortars, introducing components such as pozzolans, hydraulic limes and marble dust as aggregates, giving very similar concrete mortars to the ones used currently. In the middle Age and Renaissance, the technology developed by the Romans was lost, due to the extensive use of stone in the civil, religious and defensive constructions. It was not until the 19th century, when J. Aspdin discovered the current cement as the main hydraulic compound. Finally in the 20th century, with the appearance of molecules such as styrene, melanin, vinyl chloride and polyester, the industry began to develop polymers which were added to the binder to form special "composites".The use of polymers in cementitious matrixes give properties to the mortar such as adhesion, Currently, the result of the polymer synthesis (polivynilacetate, styrene-butadiene, vynilacrylic and epoxy resins) is that mortars have increased resistance to water attack and therefore, they increase their durability since all reactions of deterioration are minimised (ice, humidity, biological attack,...). In the present study the polymer used was redispersible polymer powder. These polymers are encapsulated and when in contact with water, they are released from the capsule forming a gel.In the repair mortars, the only hydraulic compound is the cement and nowadays, this is the main constituent of building materials. The current trend is centered in the use of higher contents of additions (lime, pozzolana, fly ash, silica, silica fume...) in order to obtain more sustainable cements. Once the composition of mortars is analyzed, the technological improvement is centred in increasing the durability of the working life. Durability is defined as the ability to resist the action of the environment, chemical, physical, and biological attacks or any process that tends to its destruction. These processes depend on factors such as the concrete porosity and the environmental exposure. In terms of porosity, it be considered, the distribution of Macropores and mesopores and pores of the concrete structure, since not all of them are capable of causing the transportation of damaging agents, causing internal stresses on the same walls and destroying the cementing matrix.In general, deterioration processes are related to the action of water, either as direct agent or as a transport vehicle. Concrete durability also depends on the type of cement and its chemical composition (cement with high addition amounts are more resistant), water/cement ratio and cement content. The standard UNE-EN 1504 consists of 10 parts and defines the products for the protection and repair of concrete, the quality control of products, physical-chemical properties and durability. Other 65 standards that provide the test methods for the evaluation of repair systems are referenced in this standard. In the second part of this thesis there is a design of experiments with different polymer mortars (with concentrations of polymer between 0 and 25%), taking a control mortar without polymer as a reference and its physico-chemical, mechanical and durable properties were studied. For mortars with low proportion of polymer, 1 component systems are used (powder polymer) and for high polymer concentrations, water dispersion polymers are used. The mechanical properties measured were: compressive strength, flexural strength, modulus of elasticity, adhesion by direct traction and expansion-shrinkage, all of them under standards UNE. As a characterization of the durability, following tests are carried out: capillary absorption, resistance to carbonation and pull out adhesion after freeze-thaw cycles. The target of this study is to select the best mortar to make a comparison between mortars with polymer (optimized amount) and mortars without polymer. To select the optimum amount of polymer the following criteria have been considered: the mortar must have a classification R4 in terms of mechanical performance as well as in durability properties against the performed cycles, always bearing in mind that the addition of polymer cannot be too high to make the mortar competitive in price. The following general conclusions were obtained from this study: - A standard mortar does not fulfill the properties to be classified as R3 or R4 - Without polymer, a mortar may fulfill R4 for most of the measured characteristics. - It is necessary to use relations w/c ratio < 0.5 to get R4 mortars - The addition of polymer always improves adhesion, abrasion, capillary absorption and carbonation resistance - The different proportions of polymer used always improve the mechanical properties and durability. - The polymer has no influence on the expansion and shrinkage of the mortar - Adhesion is improved significantly with the use of polymer. - The presence of polymer in mortars improves the properties related to the action of the water, by the increase of the cement power and therefore the cohesion. The cementitious properties decrease the porosity. As final result of this study, it was determined that the optimum amount of polymer for the second part of the study is 2.0 - 3.5%. The third part is the comparative study between two mortars: one without polymer (A mortar) and another with the optimized amount of polymer, completed in the previous part (mortar B). Once the percentage of polymer is defined, a new granular skeleton is defined, with a new dosing of aggregate sizes, for both the reference mortar, the mortar with polymers, and the tests for physical, microstructural characterization and durability, are performed, as well as trials of part 1, measurements of the microstructural properties that were studied by scanning electron microscopy (SEM) and mercury porosimetry techniques; as well as properties of the mortar in fresh State (consistency, content of entrained air and final setting time). The use of polymer versus non polymer mortar, provided the following advantages: - In fresh state: mortar with polymer presented higher consistency and least amount of entrained air, which makes a mortar more workable and more ductile as well as more resistant because hardening will leave fewer gaps in its internal structure and increase its durability. Also allow it allows a better workability because of the longer (not excessive) setting time. - Regarding the mechanical properties: improvement in adhesion. It is one of the main properties which give the polymer to mortars. This higher adhesion results in an improvement of adhesion to the substrate, minimization of possible reactions at the concrete-mortar interface and therefore an increase in the durability of the repair carried out with mortar and concrete. - Respect to microstructural properties: the porosity of mortar with polymer is less and with smaller pore size, critical to be attacked by external agents causing deterioration. No major differences were observed from the data obtained by SEM - In terms of abrasion and capillary absorption, polymer mortar presented better performance as a result of its lower porosity and its microscopic structure. - Finally behavior against attack by sulfates and seawater, as well as to carbonation, was better in the mortar with polymer because of its lower permeability and its lower porosity. To complete the study, due to the great importance of sustainability for future market facts, the life cycle of the two mortars studied was analysed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La presente tesis es un estudio analítico y numérico del electrospray. En la configuración más sencilla, un caudal constante del líquido a atomizar, que debe tener una cierta conductividad eléctrica, se inyecta en un medio dieléctrico (un gas u otro líquido inmiscible con el primero) a través de un tubo capilar metálico. Entre este tubo y un electrodo lejano se aplica un voltaje continuo que origina un campo eléctrico en el líquido conductor y en el espacio que lo rodea. El campo eléctrico induce una corriente eléctrica en el líquido, que acumula carga en su superficie, y da lugar a un esfuerzo eléctrico sobre la superficie, que tiende a alargarla en la dirección del campo eléctrico. El líquido forma un menisco en el extremo del tubo capilar cuando el campo eléctrico es suficientemente intenso y el caudal suficientemente pequeño. Las variaciones de presión y los esfuerzos viscosos asociados al movimiento del líquido son despreciables en la mayor parte de este menisco, siendo dominantes los esfuerzos eléctrico y de tensión superficial que actúan sobre la superficie del líquido. En el modo de funcionamiento llamado de conochorro, el balance de estos esfuerzos hace que el menisco adopte una forma cónica (el cono de Taylor) en una región intermedia entre el extremo del tubo y la punta del menisco. La velocidad del líquido aumenta al acercarse al vértice del cono, lo cual propicia que las variaciones de la presión en el líquido generadas por la inercia o por la viscosidad entren en juego, desequilibrando el balance de esfuerzos mencionado antes. Como consecuencia, del vértice del cono sale un delgado chorro de líquido, que transporta la carga eléctrica que se acumula en la superficie. La acción del campo eléctrico tangente a la superficie sobre esta carga origina una tracción eléctrica que tiende a alargar el chorro. Esta tracción no es relevante en el menisco, donde el campo eléctrico tangente a la superficie es muy pequeño, pero se hace importante en el chorro, donde es la causa del movimiento del líquido. Lejos del cono, el chorro puede o bien desarrollar una inestabilidad asimétrica que lo transforma en una espiral (whipping) o bien romperse en un spray de gotas prácticamente monodispersas cargadas eléctricamente. La corriente eléctrica transportada por el líquido es la suma de la corriente de conducción en el interior del líquido y la corriente debida a la convección de la carga acumulada en su superficie. La primera domina en el menisco y la segunda en el chorro lejano, mientras que las dos son comparables en una región intermedia de transferencia de corriente situada al comienzo del chorro aunque aguas abajo de la región de transición cono-chorro, en la que el menisco deja de ser un cono de Taylor. Para un campo exterior dado, la acumulación de carga eléctrica en la superficie del líquido reduce el campo eléctrico en el interior del mismo, que llega a anularse cuando la carga alcanza un estado final de equilibrio. El tiempo característico de este proceso es el tiempo de relajación dieléctrica, que es una propiedad del líquido. Cuando el tiempo de residencia del líquido en la región de transición cono-chorro (o en otra región del campo fluido) es grande frente al tiempo de relajación dieléctrica, la carga superficial sigue una sucesión de estados de equilibrio y apantalla al líquido del campo exterior. Cuando esta condición deja de cumplirse, aparecen efectos de relajación de carga, que se traducen en que el campo exterior penetra en el líquido, a no ser que su constante dieléctrica sea muy alta, en cuyo caso el campo inducido por la carga de polarización evita la entrada del campo exterior en el menisco y en una cierta región del chorro. La carga eléctrica en equilibrio en la superficie de un menisco cónico intensifica el campo eléctrico y determina su variación espacial hasta distancias aguas abajo del menisco del orden de su tamaño. Este campo, calculado por Taylor, es independiente del voltaje aplicado, por lo que las condiciones locales del flujo y el valor de la corriente eléctrica son también independientes del voltaje en tanto los tamaños de las regiones que determinan estas propiedades sean pequeños frente al tamaño del menisco. Los resultados experimentales publicados en la literatura muestran que existe un caudal mínimo para el que el modo cono-chorro que acabamos de describir deja de existir. El valor medio y la desviación típica de la distribución de tamaños de las gotas generadas por un electrospray son mínimos cuando se opera cerca del caudal mínimo. A pesar de que los mecanismos responsables del caudal mínimo han sido muy estudiados, no hay aún una teoría completa del mismo, si bien su existencia parece estar ligada a la aparición de efectos de relajación de carga en la región de transición cono-chorro. En esta tesis, se presentan estimaciones de orden de magnitud, algunas existentes y otras nuevas, que muestran los balances dominantes responsables de las distintas regiones de la estructura asintótica de la solución en varios casos de interés. Cuando la inercia del líquido juega un papel en la transición cono-chorro, los resultados muestran que la región de transferencia de corriente, donde la mayor parte de la corriente pasa a la superficie, está en el chorro aguas abajo de la región de transición cono-chorro. Los efectos de relajación de carga aparecen de forma simultánea en el chorro y la región de transición cuando el caudal se disminuye hasta valores de un cierto orden. Para caudales aún menores, los efectos de relajación de carga se notan en el menisco, en una región grande comparada con la de transición cono-chorro. Cuando el efecto de las fuerzas de viscosidad es dominante en la región de transición, la región de transferencia de corriente está en el chorro pero muy próxima a la región de transición cono-chorro. Al ir disminuyendo el caudal, los efectos de relajación de carga aparecen progresivamente en el chorro, en la región de transición y por último en el menisco. Cuando el caudal es mucho mayor que el mínimo del modo cono-chorro, el menisco deja de ser cónico. El campo eléctrico debido al voltaje aplicado domina en la región de transferencia de corriente, y tanto la corriente eléctrica como el tamaño de las diferentes regiones del problema pasan a depender del voltaje aplicado. Como resultado de esta dependencia, el plano caudal-voltaje se divide en diferentes regiones que se analizan separadamente. Para caudales suficientemente grandes, la inercia del líquido termina dominando frente a las fuerzas de la viscosidad. Estos resultados teóricos se han validado con simulaciones numéricas. Para ello se ha formulado un modelo simplificado del flujo, el campo eléctrico y el transporte de carga en el menisco y el chorro del electrospray. El movimiento del líquido se supone casi unidireccional y se describe usando la aproximación de Cosserat para un chorro esbelto. Esta aproximación, ampliamente usada en la literatura, permite simular con relativa facilidad múltiples casos y cubrir amplios rangos de valores de los parámetros reteniendo los efectos de la viscosidad y la inercia del líquido. Los campos eléctricos dentro y fuera del liquido están acoplados y se calculan sin simplificación alguna usando un método de elementos de contorno. La solución estacionaria del problema se calcula mediante un método iterativo. Para explorar el espacio de los parámetros, se comienza calculando una solución para valores fijos de las propiedades del líquido, el voltaje aplicado y el caudal. A continuación, se usa un método de continuación que permite delinear la frontera del dominio de existencia del modo cono-chorro, donde el método iterativo deja de converger. Cuando el efecto de la inercia del líquido domina en la región de transición cono-chorro, el caudal mínimo para el cual el método iterativo deja de converger es del orden del valor estimado del caudal para el que comienza a haber efectos de relajación de carga en el chorro y el cono. Aunque las simulaciones no convergen por debajo de dicho caudal, el valor de la corriente eléctrica para valores del caudal ligeramente mayores parece ajustarse a las estimaciones para caudales menores, reflejando un posible cambio en los balances aplicables. Por el contrario, cuando las fuerzas viscosas dominan en la región de transición, se pueden obtener soluciones estacionarias para caudales bastante menores que aquel para el que aparecen efectos de relajación de carga en la región de transición cono-chorro. Los resultados numéricos obtenidos para estos pequeños caudales se ajustan perfectamente a las estimaciones de orden de magnitud que se describen en la memoria. Por último, se incluyen como anexos dos estudios teóricos que han surgido de forma natural durante el desarrollo de la tesis. El primero hace referencia a la singularidad en el campo eléctrico que aparece en la línea de contacto entre el líquido y el tubo capilar en la mayoría de las simulaciones. Primero se estudia en qué situaciones el campo eléctrico tiende a infinito en la línea de contacto. Después, se comprueba que dicha singularidad no supone un fallo en la descripción del problema y que además no afecta a la solución lejos de la línea de contacto. También se analiza si los esfuerzos eléctricos infinitamente grandes a los que da lugar dicha singularidad pueden ser compensados por el resto de esfuerzos que actúan en la superficie del líquido. El segundo estudio busca determinar el tamaño de la región de apantallamiento en un chorro de líquido dieléctrico sin carga superficial. En esta región, el campo exterior es compensado parcialmente por el campo que induce la carga de polarización en la superficie del líquido, de forma que en el interior del líquido el campo eléctrico es mucho menor que en el exterior. Una región como ésta aparece en las estimaciones cuando los efectos de relajación de carga son importantes en la región de transferencia de corriente en el chorro. ABSTRACT This aim of this dissertation is a theoretical and numerical analysis of an electrospray. In its most simple configuration, a constant flow rate of the liquid to be atomized, which has to be an electrical conductor, is injected into a dielectric medium (a gas or another inmiscible fluid) through a metallic capillary tube. A constant voltage is applied between this tube and a distant electrode that produces an electric field in the liquid and the surrounding medium. This electric field induces an electric current in the liquid that accumulates charge at its surface and leads to electric stresses that stretch the surface in the direction of the electric field. A meniscus appears on the end of the capillary tube when the electric field is sufficiently high and the flow rate is small. Pressure variations and viscous stresses due to the motion of the liquid are negligible in most of the meniscus, where normal electric and surface tension stresses acting on the surface are dominant. In the so-called cone-jet mode, the balance of these stresses forces the surface to adopt a conical shape -Taylor cone- in a intermediate region between the end of the tube and the tip of the meniscus. When approaching the cone apex, the velocity of the liquid increases and leads to pressure variations that eventually disturb the balance of surfaces tension and electric stresses. A thin jet emerges then from the tip of the meniscus that transports the charge accumulated at its surface. The electric field tangent to the surface of the jet acts on this charge and continuously stretches the jet. This electric force is negligible in the meniscus, where the component of the electric field tangent to the surface is small, but becomes very important in the jet. Far from the cone, the jet can either develop an asymmetrical instability named “whipping”, whereby the jet winds into a spiral, or break into a spray of small, nearly monodisperse, charged droplets. The electric current transported by the liquid has two components, the conduction current in the bulk of the liquid and the convection current due to the transport of the surface charge by the flow. The first component dominates in the meniscus, the second one in the far jet, and both are comparable in a current transfer region located in the jet downstream of the cone-jet transition region where the meniscus ceases to be a Taylor cone. Given an external electric field, the charge that accumulates at the surface of the liquid reduces the electric field inside the liquid, until an equilibrium is reached in which the electric field induced by the surface charge counters the external electric field and shields the liquid from this field. The characteristic time of this process is the electric relaxation time, which is a property of the liquid. When the residence time of the liquid in the cone-jet transition region (or in other region of the flow) is greater than the electric relaxation time, the surface charge follows a succession of equilibrium states and continuously shield the liquid from the external field. When this condition is not satisfied, charge relaxation effects appear and the external field penetrates into the liquid unless the liquid permittivity is large. For very polar liquids, the field due to the polarization charge at the surface prevents the external field from entering the liquid in the cone and in certain region of the jet. The charge at the surface of a conical meniscus intensifies the electric field around the cone, determining its spatial variation up to distances downstream of the apex of the order of the size of the meniscus. This electric field, first computed by Taylor, is independent of the applied voltage. Therefore local flow characteristics and the electric current carried by the jet are also independent of the applied voltage provided the size of the regions that determine these magnitudes are small compared with the size of the meniscus. Many experiments in the literature show the existence of a minimum flow rate below which the cone-jet mode cannot be established. The mean value and the standard deviation of the electrospray droplet size distribution are minimum when the device is operated near the minimum flow rate. There is no complete explanation of the minimum flow rate, even though possible mechanisms have been extensively studied. The existence of a minimum flow rate seems to be connected with the appearance of charge relaxation effects in the transition region. In this dissertation, order of magnitude estimations are worked out that show the dominant balances in the different regions of the asymptotic structure of the solution for different conditions of interest. When the inertia of the liquid plays a role in the cone-jet transition region, the region where most of the electric current is transfered to the surface lies in the jet downstream the cone-jet transition region. When the flow rate decreases to a certain value, charge relaxation effects appear simultaneously in the jet and in the transition region. For smaller values of the flow rate, charge relaxation effects are important in a region of the meniscus larger than the transition region. When viscous forces dominate in the flow in the cone-jet transition region, the current transfer region is located in the jet immediately after the transition region. When flow rate is decreased, charge relaxation effects appears gradually, first in the jet, then in the transition region, and finally in the meniscus. When flow rate is much larger than the cone-jet mode minimum, the meniscus ceases to be a cone. The electric current and the structure of the solution begin to depend on the applied voltage. The flow rate-voltage plane splits into different regions that are analyzed separately. For sufficiently large flow rates, the effect of the inertia of the liquid always becomes greater than the effect of the viscous forces. A set of numerical simulations have been carried out in order to validate the theoretical results. A simplified model of the problem has been devised to compute the flow, the electric field and the surface charge in the meniscus and the jet of an electrospray. The motion of the liquid is assumed to be quasi-unidirectional and described by Cosserat’s approximation for a slender jet. This widely used approximation allows to easily compute multiple configurations and to explore wide ranges of values of the governing parameters, retaining the effects of the viscosity and the inertia of the liquid. Electric fields inside and outside the liquid are coupled and are computed without any simplification using a boundary elements method. The stationary solution of the problem is obtained by means of an iterative method. To explore the parameter space, a solution is first computed for a set of values of the liquid properties, the flow rate and the applied voltage, an then a continuation method is used to find the boundaries of the cone-jet mode domain of existence, where the iterative method ceases to converge. When the inertia of the liquid dominates in the cone-jet transition region, the iterative method ceases to converge for values of the flow rate for which order-of-magnitude estimates first predict charge relaxation effects to be important in the cone and the jet. The electric current computed for values of the flow rate slightly above the minimum for which convergence is obtained seems to agree with estimates worked out for lower flow rates. When viscous forces dominate in the transition region, stationary solutions can be obtained for flow rates significantly smaller than the one for which charge relaxation effects first appear in the transition region. Numerical results obtained for those small values of the flow rate agree with our order of magnitude estimates. Theoretical analyses of two issues that have arisen naturally during the thesis are summarized in two appendices. The first appendix contains a study of the singularity of the electric field that most of the simulations show at the contact line between the liquid and the capillary tube. The electric field near the contact line is analyzed to determine the ranges of geometrical configurations and liquid permittivity where a singularity appears. Further estimates show that this singularity does not entail a failure in the description of the problem and does not affect the solution far from the contact line. The infinite electric stresses that appear at the contact line can be effectively balanced by surface tension. The second appendix contains an analysis of the size and slenderness of the shielded region of a dielectric liquid in the absence of free surface charge. In this region, the external electric field is partially offset by the polarization charge so that the inner electric field is much lower than the outer one. A similar region appears in the estimates when charge relaxation effects are important in the current transfer region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo del estudio fue analizar el efecto del ejercicio realizado sobre una plataforma de disipación de aire comparado con el mismo ejercicio en suelo en un grupo de mujeres sanas. Material y métodos: En un estudio cuasi-experimental 14 mujeres sanas de entre 20 y 25 a?nos realizaron un mismo ejercicio en 2 condiciones diferentes separados entre sí por una semana; uno fue sobre una plataforma de disipación de aire y otro sobre el suelo. Durante las 2 pruebas se recolectaron los datos del intercambio respiratorio por un analizador de gases de circuito abierto. La frecuencia cardíaca (FC) fue registrada mediante telemetría. Muestras de sangre capilar (5 ?l) fueron extraídas cada 10 min de ejercicio utilizando un analizador de lactato portátil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Desde mediados de la década de los 80 se está investigando sobre el hormigón autocompactante. Cada día, su uso en el mundo de la construcción es más común debido a sus numerosas ventajas como su excelente fluidez ya que puede fluir bajo su propio peso y llenar encofrados con formas complicadas y muy armados sin necesidad de compactaciones internas o externas. Por otra parte, la búsqueda de materiales más resistentes y duraderos, ha dado lugar a la incorporación de adiciones en materiales a base de cemento. En las últimas dos décadas, los ensayos con los nanomateriales, ha experimentado un gran aumento. Los resultados hasta ahora obtenidos pueden asumir no sólo un aumento en la resistencia de estos materiales, pero un cambio es su funcionalidad. Estas nanopartículas, concretamente la nanosílice, no sólo mejoran sus propiedades mecánicas y especialmente sus propiedades durables, sino que pueden implicar un cambio sustancial en las condiciones de uso y en su ciclo de vida. Este trabajo tiene como principal objetivo el estudio de las propiedades mecánicas, características microestructurales y durables de un hormigón autocompactante cuando se le agrega como adición nanosílice, microsílice y mezcla binarias de ambas, como adición al cemento. Para ello se han realizado 10 mezclas de hormigón. Se utilizó como referencia un hormigón autocompactante obtenido con cemento, caliza, árido, aditivo modificador de viscosidad Se han fabricado tres hormigones con la misma dosificación pero con diferentes contenidos de nanosílice. 2,5%, 5% y 7,5% Tres dosificaciones con adición de microsílice 2,5%, 5% y 7,5% y las tres restantes con mezclas binarias de nanosílice y microsílice con respectivamente2,5%-2,5%, 5%-2,5% y 2,5%-5%, sobre el peso del cemento. El contenido de superplastificante se modificó para conseguir las características de autocompactabilidad. Para observar los efectos de las adiciones añadidas al hormigón, se realiza una extensa campaña experimental. En ella se evaluaron en primer lugar, las características de autocompactabilidad del material en estado fresco, mediante los ensayos prescritos en la Instrucción Española del hormigón estructural EHE 08. Las propiedades mecánicas fueron evaluadas con ensayos de resistencia a compresión, resistencia a tracción indirecta y módulo de elasticidad. Las características microestructurales fueron analizadas mediante porosimetría por intrusión de mercurio, el análisis termogravimétrico y la microscopía electrónica de barrido. Para el estudio de la capacidad durable de las mezclas se realizaron ensayos de resistividad eléctrica, migración de cloruros, difusión de cloruros, carbonatación acelerada, absorción capilar y resistencia al hielo-deshielo. Los resultados ponen de manifiesto que la acción de las adiciones genera mejoras en las propiedades resistentes del material. Así, la adición de nanosílice proporciona mayores resistencias a compresión que la microsílice, sin embargo las mezclas binarias con bajas proporciones de adición producen mayores resistencias. Por otra parte, se observó mediante la determinación de las relaciones de gel/portlandita, que las mezclas que contienen nanosílice tienen una mayor actividad puzolánica que las que contienen microsílice. En las mezclas binarias se obtuvo como resultado que mientras mayor es el contenido de nanosílice en la mezcla mayor es la actividad puzolánica. Unido a lo anteriormente expuesto, el estudio de la porosidad da como resultado que la adición de nanosílice genera un refinamiento del tamaño de los poros mientras que la adición de microsílice disminuye la cantidad de los mismos sin variar el tamaño de poro medio. Por su parte, en las micrografías, se visualizó la formación de cristales procedentes de la hidratación del cemento. En ellas, se pudo observar, que al adicionar nanosílice, la velocidad de hidratación aumenta al aumentar la formación de monosulfoaluminatos con escasa presencia de etringita. Mientras que en las mezclas con adición de microsílice se observan mayor cantidad de cristales de etringita, lo que confirma que la velocidad de hidratación en estos últimos fue menor. Mediante el estudio de los resultados de las pruebas de durabilidad, se observó que no hay diferencias significativas entre el coeficiente de migración de cloruros y el coeficiente de difusión de cloruros en hormigones con adición de nano o microsílice. Aunque este coeficiente es ligeramente menor en mezclas con adición de microsílice. Sin embargo, en las mezclas binarias de ambas adiciones se obtuvo valores de los coeficientes de difusión o migración de cloruros inferiores a los obtenidos en mezclas con una única adición. Esto se evidencia en los resultados de las pruebas de resistividad eléctrica, de difusión de cloruros y de migración de cloruros. Esto puede ser debido a la suma de los efectos que producen el nano y micro adiciones en la porosidad. El resultado mostró que nanosílice tiene un papel importante en la reducción de los poros y la microsílice disminuye el volumen total de ellos. Esto permite definir la vida útil de estos hormigones a valores muy superiores a los exigidos por la EHE-08, por lo que es posible reducir, de forma notable, el recubrimiento exigido en ambiente de alta agresividad asegurando un buen comportamiento en servicio. Por otra parte, la pérdida de masa debido a los ciclos de congelación-descongelación es significativamente menor en los hormigones que contienen nanosílice que los que contienen microsílice. Este resultado está de acuerdo con el ensayo de absorción capilar. De manera general, se puede concluir que son las mezclas binarias y más concretamente la mezcla con un 5% de nanosílice y 2,5% de microsílice la que presenta los mejores resultados tanto en su comportamiento resistente con en su comportamiento durable. Esto puede ser debido a que en estas mezclas la nanosílice se comporta como un núcleo de activación de las reacciones puzolánicas rodeado de partículas de mayor tamaño. Además, el extraordinario comportamiento durable puede deberse también a la continuidad en la curva granulométrica por la existencia de la microsílice, el filler calizo, el cemento, la arena y la gravilla con tamaños de partículas que garantice mezclas muy compactas que presentan elevadas prestaciones. Since the middle of the decade of the 80 is being investigated about self-consolidating concrete. Every day, its use in the world of construction is more common due to their numerous advantages as its excellent fluidity such that it can flow under its own weight and fill formworks with complicated shapes and congested reinforcement without need for internal or external compactions. Moreover, the search for more resistant and durable materials, has led to the incorporation of additions to cement-based materials. In the last two decades, trials with nanomaterials, has experienced a large increase. The results so far obtained can assume not only an increase in the resistance of these materials but a change is its functionality. These nano particles, particularly the nano silica, not only improve their mechanical properties and especially its durable properties, but that may imply a substantial change in the conditions of use and in their life cycle. This work has as its main objective the study of the mechanical properties, the microstructural characteristics and durability capacity in one self-compacting concrete, when added as addition to cement: nano silica, micro silica o binary mixtures of both. To this effect, 10 concrete mixes have been made. As reference one with a certain amount of cement, limestone filler, viscosity modifying additive and water/binder relation. Furthermore they were manufactured with the same dosage three mix with addition of 2.5%, 5% and 7.5% of nano silica by weight of cement. Other three with 2.5%, 5% and 7.5% of micro silica and the remaining three with binary mixtures of 2.5%-2.5%, 5%-2.5% and 2.5%-5% of silica nano-micro silica respectively, b weight of cement, varying only the amount of superplasticizer to obtain concrete with characteristics of self-compactability. To observe the effects of the additions added to the concrete, an extensive experimental campaign was performed. It assessed, first, the characteristics of self-compactability of fresh material through the tests prescribed in the Spanish Structural Instruction Concrete EHE 08. The mechanical properties were evaluated by compression strength tests, indirect tensile strength and modulus of elasticity. The microstructural properties were analyzed by mercury intrusion porosimetry, thermogravimetric analysis and scanning electron microscopy. To study the durability, were performed electrical resistivity tests, migration and diffusion of chlorides, accelerated carbonation, capillary suction and resistance to freeze-thaw cycles. The results show that the action of the additions generates improvements in the strength properties of the material. Specifically, the addition of nano silica provides greater resistance to compression that the mix with micro silica, however binary mixtures with low addition rates generate higher strengths. Moreover, it was observed by determining relationships gel/portlandite, that the pozzolanic activity in the mixtures with nano silica was higher than in the mixtures with micro silica. In binary mixtures it was found that the highest content of nano silica in the mix is the one with the highest pozzolanic activity. Together with the foregoing, the study of the porosity results in the mixture with addition of nano silica generates a refinement of pore size while adding micro silica decreases the amount thereof without changing the average pore size. On the other hand, in the micrographs, the formation of crystals of cement hydration was visualized. In them, it was observed that by adding nano silica, the speed of hydration increases with increasing formation monosulfoaluminatos with scarce presence of ettringite. While in mixtures with addition of micro silica, ettringite crystals are observed, confirming that the hydration speed was lower in these mixtures. By studying the results of durability testing, it observed that no significant differences between the coefficient of migration of chlorides and coefficient of diffusion of chlorides in concretes with addition of nano or micro silica. Although this coefficient is slightly lower in mixtures with addition of micro silica. However, in binary mixtures of both additions was obtained values of coefficients of difusion o migration of chlorides lower than those obtained in mixtures with one of the additions. This is evidenced by the results of the tests electrical resistivity, diffusion of chlorides and migration of chlorides. This may be due to the sum of the effects that produced the nano and micro additions in the porosity. The result showed that nano silica has an important role in the pores refining and the micro silica decreases the total volume of them. This allows defining the life of these concretes in values to far exceed those required by the EHE-08, making it possible to reduce, significantly, the coating required in highly aggressive environment and to guarantee good behavior in service. Moreover, the mass loss due to freeze-thaw cycles is significantly lower in concretes containing nano silica than those containing micro silica. This result agrees with the capillary absorption test. In general, one can conclude that the binary mixture and more specifically the mixture with 5% of nano silica and 2.5% silica fume is which presents the best results in its durable behavior. This may be because in these mixtures, the nano silica behaves as cores activation of pozzolanic reactions. In addition, the durable extraordinary behavior may also be due to the continuity of the grading curve due to existence of micro silica, limestone filler, cement, sand and gravel with particle sizes that guarantees very compact mixtures which have high performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tesis se centra en la generación de ondas superficiales subarmónicas en fluidos sometidos a vibración forzada en el régimen gravitatorio capilar con líquidos de baja viscosidad. Tres problemas diferentes han sido estudiados: un contenedor rectangular con vibración horizontal, la misma geometría pero con una combinación de vibración vertical y horizontal y un obstáculo completamente sumergido vibrado verticalmente en un contenedor grande. Se deriva una ecuación de amplitud desde primeros principios para describir las ondas subarmónicas con forzamiento parámetrico inducido por la vibración. La ecuación es bidimensional mientras que el problema original es tridimensional y admite un forzamiento espacial no uniforme. Usando esta ecuación los tres sistemas han sido analizados, centrándose en calcular la amplitud crítica, la orientación de los patrones y el carácter temporal de los patrones espaciotemporales, que pueden ser estrictamente subarmónicos o cuasiperiodicos con una frecuencia de modulación temporal. La dependencia con los parámetros adimensionales también se considera. La teoría será comparada con los experimentos disponibles en la literatura. Abstract This thesis focus on the generation of subharmonic surface waves on fluids subject to forced vibration in the gravity-capillary regime with liquids of small viscosity. Three different problems have been considered: a rectangular container under horizontal vibration; the same geometry but under a combination of horizontal and vertical vibration; and a fully submerged vertically vibrated obstacle in a large container. An amplitude equation is derived from first principles that fairly precisely describes the subharmonic surfaces waves parametrically driven by vibration. That equation is two dimensional while the underlying problem is three-dimensional and permits spatially nonuniform forcing. Using this equation, the three systems have been analyzed, focusing on the calculation of the threshold amplitude, the pattern orientation, and the temporal character of the spatio-temporal patterns, which can be either strictly subharmonic or quasi-periodic, showing an additional modulation frequency. Dependence on the non-dimensional parameters is also considered. The theory is compared with the experiments available in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En el estudio de la propagación transversal de una radiación luminosa a través de un capilar con cristal líquido nemático, y cuyas moléculas se encuentran orientadas homeotrópicamente con respecto a las paredes internas de dicho capilar es necesario conocer de forma exacta la distribución espacial del director de cada una de las moléculas contenidas en el mismo. Esta distribución ha sido obtenida de forma empírica por Scudieri interpretando los resultados mediante la suposición de "lente delgada". Experimentalmente, mediante técnicas interferométricas, se obtienen dos grupos de franjas correspondiendo uno al índice de refraccción ordinario y siendo el otro función del ordinario y del extraordinario. El análisis de estas franjas es de una gran importancia a la hora de aplicar estructuras como la presente en Optica Integrada, ya que de ellas se puede inferir cuál es la respuesta de las moléculas de cristal líquido frente a campos externos, conocidos los valores del índice de refracción.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente trabajo de investigación determina las características de la cerámica que más eficientemente se comporta a evaporación y a enfriamiento. Con el objeto de ser empleado como material integrado en la envolvente de los edificios para reducir su carga de refrigeración. La cerámica es un buen material para ser empleado para la refrigeración por evaporación. Es un sólido poroso inerte que, tras ser sometido a cocción a temperaturas por encima de los 900ºC, resulta uno de los materiales que mejor se comportan como contenedor de agua en su red capilar para, posteriormente, ir liberándola por evaporación al mismo tiempo que se enfría su superficie. La metodología general de investigación, se divide en tres etapas: Búsqueda y análisis del estado de la técnica y de la investigación. Estudio teórico de la eficacia del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura. Etapa experimental, desarrollada en tres fases: una primera de definición de los parámetros determinantes del Enfriamiento Evaporativo en piezas cerámicas, una segunda de selección cerámica y diseño de ensayos experimentales y una tercera de caracterización de la cerámica bajo criterios de evaporación y de enfriamiento. El recorrido por el estado de la cuestión ha identificado las aplicaciones tecnológicas y las investigaciones científicas que emplean el Enfriamiento Evaporativo con piezas cerámicas como técnica de enfriamiento. Como resultado se ha obtenido una tabla de clasificación de sistemas de enfriamiento evaporativo y se ha constatado que el conjunto de las aplicaciones están centradas en el diseño de piezas o sistemas pero que, sin embargo, no existe una definición de las características de la cerámica para su empleo como material de enfriamiento por evaporación. El estudio teórico de la eficacia del empleo del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura se ha realizado mediante cálculos de porcentaje de ampliación de horas en confort con empleo de técnicas de enfriamiento evaporativo directo e indirecto (EED y EEI). Como resultado se obtienen unos mapas para el ámbito español de potencial de aplicación del EED y EEI. Los resultados permiten afirmar que mediante EE se puede llegar a confort en prácticamente la totalidad de las horas de los días más cálidos del año en muchas localidades. La metodología experimental se ha desarrollado en tres fases. En la fase inicial, se han definido los parámetros determinantes del enfriamiento evaporativo en un medio cerámico mediante ensayos experimentales de capacidad de evaporación y de caracterización. Se realizaron un total de 12 ensayos. Se determinó que el material cerámico tiene una gran influencia en la capacidad de evaporación y enfriamiento en las piezas cerámicas, apoyando la hipótesis inicial y la necesidad de caracterizar el material. La primera fase empírica se centró en la selección cerámica y el diseño de los ensayos experimentales de comportamiento hídrico. Se seleccionaron muestras de 5 tipos de cerámica. Se realizaron 4 tipos de ensayos de caracterización y 6 tipos de ensayos experimentales de comportamiento hídrico (total 123 muestras ensayadas). Los resultados obtenidos son de dos tipos, por un lado, se determinó cuál es el tipo de cerámica que más eficientemente se comporta a EE y, por otro, se rediseñaron los ensayos de la última fase experimental. Para la segunda fase experimental se seleccionaron cerámicas de fabricación manual abarcando el mayor número de localidades del ámbito español. Se realizaron ensayos de caracterización de 7 tipos y ensayos de comportamiento hídrico de 5 tipos (total 197 muestras ensayadas). Los resultados de caracterización han permitido aportar unos rangos de las características de la cerámica que más eficientemente se comporta en los ensayos de comportamiento hídrico. Al final de la investigación se ha caracterizado el material cerámico aportando características acerca de su porosidad, capacidad de absorción, color, rugosidad y mineralogía. Así como datos de referencia de su comportamiento hídrico. Además se ha desarrollado una metodología de ensayo específica que permite evaluar la capacidad de enfriamiento eficiente de una pieza cerámica. ABSTRACT The purpose of this research is to determine the characteristics of ceramic materials having the most efficient performance in terms of evaporation and cooling, so that they can be integrated in building envelopes to reduce cooling loads. Ceramics are suitable materials for cooling through passive evaporation. After being fired at temperatures over 900 °C (1,652 °F), the capillary network of this inert porous medium turns to be excellent to retain water, which is progressively liberated by evaporation while the material surface gets colder. Research methodology has involved the following steps: Search and analysis on the state of the art in technology and research. Theoretical study on the efficiency of evaporation as passive cooling strategies in buildings. Experimental stage developed in three phases, namely: definition of parameters determining evaporative cooling in ceramic elements; ceramic selection and design of experimental tests; characterization of ceramic materials under evaporation and cooling criteria. Search and analysis on the state of the art in this field have been useful to identify technology applications and scientific research where ceramics are employed for evaporative cooling. The resulting table shows that applications are wholly focused on the design of pieces and systems. Nonetheless, there is lack of definition of material characteristics in this scope. The theoretical study on efficiency of the passive strategy applied to buildings has been realized by calculation of the percentage increase in comfort hours through direct/indirect evaporative cooling techniques (DEC/IEC). The mapping of their potential application in Spain clearly shows that comfort conditions can be reached in almost all the hours of the hottest days in many towns. In the initial phase of the experimental stage, parameters determining evaporative cooling in ceramic media have been defined. For this purpose, characterization tests and evaporation and cooling rates experiments have been carried out; the number of samples tested amounted to 12. It has been concluded that material characteristics have great influence on these rates, which supports the initial hypothesis and the need for their characterization. The first empirical phase has focused on ceramic selection and design of water behaviour experimental methods. The samples covered five different kinds of ceramic materials. Four different characterization tests and six different water behaviour experiments were carried out; the number of samples tested amounted to 123. The experimental testing procedures served to determine the most efficient types of ceramic materials in terms of evaporative cooling efficiency and, at the same time, made it necessary to change the original designed experimental test for the last phase. In the second phase, a number of varied hand-made ceramic tiles have been selected. Seven different characterization tests and five different water behaviour tests were carried out; the number of samples amounted to 197. The results of characterization served to establish a range of features in ceramic materials according to their efficiency in water behaviour experiments. Finally, ceramic materials have been characterized according to porosity, water absorption, colour, surface roughness and mineralogy. Also, reference data regarding water behaviour have been included. Moreover, an innovative and specific experimental test to evaluate cooling efficiency of ceramic tiles has been developed.